Direct Wire
Power supply cable must match power supply (4-wire or
3-wire) and be:
■ Flexible armored cable or nonmetallic sheathed copper
cable (with ground wire), covered with exible metallic
conduit. All current-carrying wires must be insulated.
■ 10-gauge solid copper wire (do not use aluminum).
■ At least 5 . (1.52 m) long.
ELECTRIC DRYER INSTALLATION REQUIREMENTS
■ To contact a qualied electrical installer.
■ To be sure that the electrical connecon is adequate
and in conformance with the Canadian Electrical Code,
C22.1 – latest edion and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Associaon, 178 Rexdale Blvd., Toronto, ON M9W
1R3 CANADA.
■ To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A me-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
■ This dryer is equipped with a CSA Internaonal
Cered Power Cord intended to be plugged
into a standard 14-30R wall receptacle. The
cord is 5 (1.52 m) in length. Be sure wall
receptacle is within reach of dryer’s nal
locaon.
■ Do not use an extension cord.
If you are using a replacement power supply cord,
it is recommended that you use Power Supply Cord
Replacement Part Number 8579325. For further
informaon, please reference the service numbers
located in the “Assistance or Service” secon.
4-wire
receptacle
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.