Loading ...
Loading ...
Loading ...
31
ELECTRONIC CONTROL SETUP INSTRUCTIONS

1 00 Cycles in HUNDREDS 1 02 = 200
2 00 Cycles in ONES 2 25 = 25
TOTAL CYCLES = 225
This is “VIEW ONLY” and cannot be cleared.
Press the PERM PRESS buon once to advance to next code.
If money counter (1.0C or 1.C0) is selected, the following is

3 00 Dollars in HUNDREDS 3 01 = $100.00
4 00 Dollars in ONES 4 68 = $ 68.00
5 00 Number of CENTS 5 75 = $ 00.75
TOTAL = $168.75
END of SET-UP PROCEDURES

1. Close the service access door.
2. Disconnect dryer from power before reinstalling the AA1
connector, if it was removed.
3. Remove the manual set-up card.
Diagnostic Codes
If the set-up mode is entered and one of the following has
previously occurred, the appropriate diagnosc code will be
in the display.
Dryer Display Explanation
d 5 Blocked coin 1 or coin drop UI control
circuit failure (coin recognion and
customer display disabled while
blockage persists).
d 9 Voltage detected below 90 VAC for
8 seconds.
d 13 Blocked coin 2 or coin drop UI control
circuit failure (coin recognion and
customer display disabled while
blockage persists).
d 16 Not receiving communicaons
from installed debit card reader in
Enhanced (Generaon 2) Debit mode.
F 01 Dryer motor control circuit error
(cycles and price display disabled unl
diagnosc code is manually cleared).
The control doesn’t know if the motor
relay is bad (stuck on), the motor relay
drive circuit is bad (shorted), causing
the motor relay to stay on, or the
motor relay feedback circuit is bad.
F 22 Exhaust thermistor open, temperature
drops below 18°F (>50 kΩ) for 1
minute in Run mode, or immediately
in Factory Diagnosc Mode.
F 23 Exhaust thermistor shorted,
temperature above 250°F (<500Ω) for
1 minute in Run mode, or immediately
in Factory Diagnosc Mode.
F 70 UI is not receiving communicaons
from CCU (cycles and price display
disabled while error persists or is
manually cleared).
F 71 CCU is not receiving communicaons
from UI (cycles and price display
disabled while error persists or is
manually cleared).
F 73 UI Microprocessor is not able to read
or verify EEPROM (cycles and price
display disabled unl diagnosc code
is manually cleared).
F 74 UI EEPROM memory is a CRC failure
(cycles and price display disabled unl
diagnosc code is manually cleared).
Loading ...
Loading ...
Loading ...