ADJUSTMENTS
Always disconnect the appliance from
the electricity supply before making any
adjustment.
All seal must be replaced by the technician
following any adjustment or regulation.
The adjustment of the reduce rate (simmer)
must be undertaken only with burners
functioning on natural gas while in the case of
burners functioning on L.P.G, the screw must
be locked down fully (in clockwise direction).
“Primary air adjustment” on hob gas burners
is unnecessary.
TAPS
All gas taps are male cone type with only one way of
passage. Adjustment of the “Reduced rate” position
as follows:
Turn the burner on and place the knob on the
“Reduced rate” position (small ame).
Remove the knob (A) of the tap which is attached by
simply applying pressure to the rod.
•• In the case of taps with ame failure device, the
adjustment screw (V) is over or on the side of the
stem (g. 22).
Check that the ame does not go out when the knob
is sharply switched from the “Full on” to “Reduced
rate” positions.
INSTRUCTIONS FOR THE INSTALLER
CONVERSIONS
REPLACING THE INJECTORS
Our burners can be adapted to different types of
gas by simply installing the injectors suitable for
the gas you want to use. To help the installer, in the
table <TECHNICAL FEATURES> paragraph,gives
the burner nominal heat input, injector diameter and
operating pressure of the different gas types.
Comply with the following instructions:
Injector replacement - Hob burners.
To change the injectors on the hob, remove the burner
cup and head and with a 7 mm Ø socket spanner
replace them (g.23)..
After having replaced the injectors, it will be
necessary to proceed with burner adjustment
as explained in the previous paragraphs. The
technician must replace any seals after the
adjustments have been made.