Drain Pump Installation
NOTE: Do not kink, smash, or damage tubes or wires during
installation.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Unplug ice maker or disconnect power.
2. Remove rear panel. See “Rear Panel” illustration for screw
locations. Pull rear panel away from the drain tube and
discard. For standard model, discard the rear panel. For
custom panel model, set aside the rear panel (it will be reused
in a later step).
Rear Panel
A. Screw Iocations for standard model
B. Screw Iocations for custom panel model
3. Remove the old drain tube and clamp attached to the ice
maker bin.
NOTE: Discard old drain tube and clamp.
4. Install new drain tube (5/8" I.D. x 5 1/8") from ice maker bin to
drain pump reservoir inlet using new adjustable clamps. See
“Drain Tube” illustration.
NOTE:
Do not kink.
Trim tube length if required.
Drain Tube
A. 7/8" adjustable
hose clamp
B. Drain tube (ice
bin to drain
pump)
C. 7/8" adjustable hose clamp
D. Drain pump reservoir inlet
5. Slide drain pump into the ice maker base on the right side.
The pump mounting tab should slip into the rectangular slot in
the ice maker base. It will be necessary to tip the pump slightly
to slip into the slot. See “Drain Pump Mounting Tab Slot”
illustration.
Drain Pump Mounting Tab Slot
A. Mounting tab slot
Loading ...