VZA01A117
READ AND SAVE THESE INSTRUCTIONS
CEILING FAN INSTALLATION MANUAL

CONTENTS
01 IMPORTANT SAFETYINSTRUCTIONS 1
02 PACKAGE CONTENTS
2
03 BEFORE INSTALLATION
3
04 ASSEMBLING THE CEILING BRACKET
4
05 ASSEMBLING THE DOWNROD
4-5
06 HANGING YOUR CEILING FAN BODY
6
07 ASSEMBLING THE BLADES
7
08 ASSEMBLING THE LIGHT KIT
8
09 ASSEMBLING THE LIGHT SHADE
8
10 REMOTE CONTROL OPERATION
9-10
11 APP OPERATION
11
12 PRODUCT SIZE
12
14 CLEANING AND MAINTENANCE
13
13 FCC STATEMENT
12
15 TROUBLESHOOTING
13

1
1. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount directly to a structural framing member
or to an outlet box marked acceptable for fan support of 15.9kg (35 lbs). For outlet box mounting, use mounting screws
provided with the outlet box.
2. To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch location. If you can not lock the circuit breakers in the off
position,
securely fasten a prominent warning device, such as a tag, to the service panel.
3. To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
4. WARNING: To reduce the risk of personal injury, do not bend the blade brackets when instaling the blade brackets,
balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
5. This appliance can beused by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision. It is recommended that children be
supervised to ensure that they are not using the appliance improperly.
6. WARNING: To reduce the risk of fire or electric shock or injury to persons, do not use replacement parts that have
not been recommended by the manufacturer (e.g.parts made at home using a 3D printer).
7. Read all instructions and safety information before installing your new fan. Review the accompanying assembly
diagrams.
8. Before installing the fan, disconnect the power by removing fuses or turning off circuit breakers.
9. Make sure all electrical connections comply with local law and the national electrical code. Please hire a qualified
electrician or consult a do it yourself wiring handbook if you are unfamiliar with installing electrical wiring.
10. Make sure the instalation site is roomy enough to allow fan blades to rotate. There is at least seven feet from the
floor to fan blades' tips.
11. If you are mounting the fan on a celing outet box, please use a metal outlet box. Secure the box directly to the
building structure. The outlet box and its support must be able to support the rotating fan (at least 35Ibs). Do not use a
plastic outlet box. Attach the mounting bracket using the ceiling outlet box's hardware.
12. After installing the fan, make sure all the connections are secured so that the fan won't fall.
13. Do not insert anything between fan blades while the fan is operating.
14. Turn the fan off and wait for it to stop before reversing fan's rotating direction.
15. WARNING: To reduce the risk of electrical shock and personal injury, do not install the fan on a sloped ceiling and
do not use this fan with any solid-state fan speed control device, or rheostat. You must install the outlet box using the
two steel screws and lock washers coming with the fan.
16. All wiring must be in accordance with national and local electrical codes ANSI/NFPA70. If you are unfamiliar with
wiring, use a qualified electrician.
17. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipme-
nt-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
18. The splices after being made should be turned upward and pushed carefully up into the outlet box.
19. Instructions for supply connections: the white conductor of a fan identified as grounded conductor to be connected
to a grounded conductor of power supply, the black conductor of fan identified as ungrounded conductor to be connect-
ed to an ungrounded conductor of power supply, the green conductor of fan identified for equipment grounding to be
connected to an equipment-grounding conductor.
20. When mounted directly to the building structure, appliance installation shall not expose combustible material and
do not install the appliance to a ceiling with combustible finish. The installation of the appliance can not leave the
wood of the rafters or any thermal insulation exposed to the interior of the room.
21. To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before instaling light kit.
IMPORTANT SAFETYINSTRUCTIONS
SPECIFICATIONS
SKU#
Fan Blade Span
120VAC 60HzVZA01A117
54W(Fan 30W, Light 24W)
Voltage
Rated Wattage52"

2
1 X Ceiling Bracket
PARTS
1 X Ceiling Fan Body
1 X Light Kit
1 X Light Shade
5 X Blades
5 X Blades Brackets
1 X Downrod Ball
1 X 6-inch Downrod
1 X 10-inch Downrod
1 X Canopy
1 X Canopy Cover
1 X Coupling cover
ACCESSORIES
4 X ST5 X 35mm
Wood screws
3 X
Plastic wire nuts
1 X
Balanced parts package
16 X M5 X 6 mm
Blade screws
2 X 8-32UNC X 32mm
Mounting screws
2 X
Ø16 X Ø4.5 X 1.5mm
Washers
2 X M4
Spring washers
16 X M5
Blade decorative nuts
1 X Controller
1 X
Remote control
(Battery included)
2 X
Screws
1 X
Remote control holder
2 X
Expansion screws
PACKAGE CONTENTS

3
TOOLS NEEDED (NOT INCLUDED)
Ladder Phillips Screwdriver Wire Stripper Drill
CHECK THE ROOM DIMENSIONS
30 inches
from blade tip to nearest
wall or obstruction
7 feet
from bottom edge
of blade to the floor
Make sure your room ceilingangle is less than 15°
CHECK THE ROOM CEILING ANGLE
15°
BEFORE INSTALLATION

4
Step 1:
Remove the pre-installed setscrews
and downrod pin.
Step 2:
Insert the canopy, canopy cover and the coupling cover to
the downrod. Pass all the wires to one side of the
horizontal bar in the downrod to prevent excessive wire
tangling.
Canopy
Canopy cover
Coupling cover
ASSEMBLING THE DOWNROD
WARNING: FAN FALL HAZARD
ALWAYS tighten setscrew with screwdriver. DO NOT hand tighten setscrew. CHECK the setscrew is tight
using screwdriver each time you change fan direction.
ASSEMBLING THE CEILING BRACKET
WARNING:
To avoid possible electrical shock, before installing your ceiling fan, disconnect the power by turning off the circuit
breakers to the outlet box associated with the wall switch location.
Option 1: Concrete ceiling
Use 2 mounting screws and washers provided when:
Securing to existing ceiling fan-rated outlet box.
Make sure it is securely installed and is acceptable
for fan support of 15.9kg (35 lbs) or less.
Option 2: Wood ceiling
Use 4 wood screws when:
Securing to support structure with apporved electrical
outlet box. Drill 4 holes in support structure to aid in
securing ceiling bracket.
Wood
Screws

5
Step 3:
Carefully slide the downrod into the yoke of the
motor assembly. Align the holes in the downrod.
Carefully re-installthe downrod pin and clip.
Step 4:
Tighten the setscrew with a screwdriver.
Step 5:
Put down the coupling cover.
NOTE: The downrod ball has been pre-installed on the 6-inch downrod. If you wish to move it to the 10-inch downrod,
please follow these steps. Note: If the downrod is too long, it will increase the shaking.
a. Loosen and remove the two screws on the downrod
ball from the 6-inch downrod.
c. Install the downrod ball onto the 10-inch downrod
and securely insert the horizontal bar in its designated
position.
b. Lift the downrod upwards, then remove the horizontal
bar, and detach the downrod ball from the 6-inch downrod.
d. Insert the first perforated long screw tightly, and then
insert the second short screw tightly.
ASSEMBLING THE DOWNROD

Step 2:
a. Connect the wires (white to white, black to
black) from the ceiling to the controller using
wire nuts.
b. Connect the three grounding wires (green,
green/yellow stripe,or bare copper) coming
from the ceiling, downrod, and ceiling bracket
using a wire nut.
c. Connect the motor wires and light wires to
the controller.
d. Slide the controller between the mounting
bracket and the top of the downrod.
Note: Use the canopy to place the
exceeded wires.
WIRING MUST BE UP TO CODE. All wiring
must be in accordance with national and
local electrical codes. If you are unfamiliar
with wiring or in doubt, consult a
qualified electrician.
Motor wires
Light wires
6
Step 1:
Place the downrod ball into
the ceiling bracket. Make sure
the downrod ball slot matches
the inner lock.
Rotate the downrod until it
secured.
Step 3:
Install the canopy to the screws of the mounting bracket, tighten the screws and cover the canopy cover.
HANGING YOUR CEILING FAN BODY

7
ASSEMBLING THE BLADES
Step 1:
Remove 10 screws from the ceiling fan body,
place the screws for subsequent.
Attach the fan blade to the blade bracket using 3 blade
bracket screws and
decorative nuts provided, tighten them
firmly. Complete 5 blades assembly.
Step 2:
Step 3:
Attach the blade assembly to the fan body using 2 removed screws and tigtem firmly. Install 5 blades.

8
ASSEMBLING THE LIGHT KIT
ASSEMBLING THE LIGHT SHADE
NOTE:Turn on the circuit breakers to the outlet box associated with the wall switch location,
then turn on the wall switch and check if the ceiling fan starts flashing white light.
If it does not flash a white light, please, check all wiring connections for any wrong connections.
If it does flash a white light, please, proceed to the next step.
Step 1:
Remove 3 screws from the ceiling fan body,
place the screws for subsequent.
Step 2:
Connect the wires of the ceiling fan body with light kit. Attach
the light kit to the ceiling fan body using removed 3 screws
and tighten firmly.
Insert the light shade into the light kit and securely fasten it into place.

Brightness Switch
Press to increase brightness
Press to decrease brightness
Color Temperature
Change and Pair Code
Control buttons
9
Install 2 AAA 1.5 volt battery (Included).
Note: To prevent damage to remote control, remove the battery
if not used for a long time). Store the remote control away from
excessive heat or humidity.
REMOTE CONTROL OPERATION
Power Switch
Press to turn
the power ON/OFF
Fan Speed Setting
(1 to 6)
Press to change
the speed
Forward and Reverse
Press to change the airflow direction.
Forward: the airflow will be directed
downwards, for cooling in summer.
Reverse: The airflow will be directed
upwards assisting in the circulation of
warm air, for energy conservation in
winter.
Fan Stopped and Clear Code
Light Switch
1. Press to turn the fan OFF.
2. Press to clear code.
Press to turn the light ON/OFF
CCT Switch
Press to increase CCT
Press to decrease CCT
1. Press to quickly change CCT:
warm white / cool white / daylight white
2. Press
within 5 seconds
to repair code.
Sound Switch
Press and hold for 5 seconds
to switch sound
Quick Timer Settings
(1H,2H)
Press 1H to quickly add a
1-hour Timer to turn off
your ceiling fan blades.
Press 2H to quickly add a
2-hour Timer to turn off
your ceiling fan blades

10
INSTALL THE REMOTE CONTROL HOLDER
Use the two holes on the holder as a guide to drill two
corresponding holes in the flat wall.
Insert two expansion screws into the holes and
make them level with the flat wall.
Align the two holes on the holder with the two holes
on the wall. Insert the two screws into the holes and
tighten them using a screwdriver.
Store your remote control.
REMOTE CONTROL OPERATION
REMOTE CONTROL MATCHING CODE:
Power on the receiver, press the key within 5 seconds of the light on, when you hear a beep or a light flashes,
the code match is successful. If you need to match the code a second time, you need to wait 30 senconds before
turning on the power and repeat above operation.
NOTICES
●
●
RF wireless digital transmission technology is adopted to realize the one-to-one control providing a rate of
coincident code less than 1/50000. Same code number is attached to the back of the emitter and the receiver.
It is required to return a pair of the same code number of emitter / receiver to the manufacturer for repair service in
case of any damage.
1. When the emitter is unable to remotely control the controller, please check whether the switch batteries are in
good contact, whether they are fixed properly and whether they run out of use.
2. When the emitter is unable to remotely control the receiver, please check whether there is other remote control
products around the space and check whether the keys are pressed down, because same nature of remote control
product may cause interference with each other resulting in poor receiving effect. Taking away such articles will
normalize the remote control function. (the infrared remote controller is not included).
3. Please use this product under applicable voltage. Too low voltage will lead to failure of the remote controller to
work (Please refer to the product label for the voltage range and related parameters).
4. Please take out the batteries if you will no use this product for a long time.
In a sufficient space, you can use the receiver at any angle, no worry about the direction.

11
APP OPERATION
Step 1: Download the APP: Scan the QR code→open the browser→select the version to download.
Step 2: Open the APP→select a room→Click on →select "fan light" →enter the equipment
name (such as fan light)→OK
a. Click the buttons within 5 seconds when the light turn on, if the light
flicks/when you hear a beep, it means the fan and app successfully
paired. (APP Control Distance: within 65ft (20m))
b. The previous phone will jump out automa-tically if the next phone is
paired successfully.
APP button function description:
Step 3: Click on enter
Light Switch Fan Switch
Adjust Fan Speed Adjust Light Brightness
Adjust Light CCT
Step 4: Pair code with the app.
Pairing Button
Timer Setting Mode
Natural Wind Mode
Sleep Wind Mode
The fan rotates in reverse
to distribute warm air
throughout a room.
The fan rotates forward.
White light
Yellow light
Natural light
Night light,10% bightness.
Not apply to these function follow:
Power Switch
R
G
B

Dia 6.3 in. (Ø160mm)
10.2 in. (260mm)
13.3 in. (338mm)
Dia12.2 in. (Ø310mm)
52 in. (1320mm)
Dia 1.04 in. x 6 in. or 10 in.
(Ø26.5mm x150mm or 250mm)
PRODUCT SIZE
12
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference.
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Please note that changes or modifications of this product is not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC STATEMENT

Clean the motor housing and blades
with a soft brush or lint-free cloth to
avoid scratching the finish.
At least twice each year,lower the
canopy to check the downrod assembly
and tighten all screws on the fan.
Shut off the main power supply before you begin any maintenance task.
DO NOT use water or a damp cloth to clean the fan.
Cleaning products may damage the finishes.
CLEANING AND MAINTENANCE
13
Problem
Solution
Fan Doesn't Work
· Make sure the power switch is on.
· Check the circuit breaker to ensure the power is turned on.
· Make sure the blades spin freely.
· Turn off power from the circuit breaker, then loosen the canopy and
check all the connections according to the wiring diagram
Excessive Wobbling
· Make sure the blades are properly installed on the ceiling fan body.
· Turn the power off, support the fan carefuly, and check that the downrod
ball is properly seated.
Remote Control of
Fan is Erratic
· Make sure the battery is installed correctly. lf the command indicator
light keeps flashing, indicating low battery, install a fresh battery.
Remote Only Works
Close to Fan
· Change battery
Noisy Operation
· Make sure the blades are properly installed.
· Check to see if any of the blades are cracked. lf so, replace all of the
blades
If your problem is not listed or still persists, please contact our Customer Support.
TROUBLESHOOTING

We’re Here to Help!
1 (888) 275-3352
Customersupport@Vaczon.com
https://vaczon.com