www.parrotuncle.com
English
F6018CR
F6018BK

Sicherheit information
1. To reduce the risk of an electrical blow, electricity on the
2. All wiring must correspond to the NASI/NFPA 70-1999
approved electrician.
3.
assembled safely and 35 pounds (15.9 kilos) must be able
to transport reliably. Use only output boxes listed with
labeling
"Accepted for fans with a weight of £ 35 (15.9 kilos) or less."
4. The fan must be installed with a minimum distance of 2.1 m
(7 feet) from the posterior edge of the blades to the floor.
5. Do not operate the reverse switch if the fan blades are
moving. You have to turn off the fan and stop the blades
6. Do not place objects on the road to blades.
7. To avoid lesions or damage to the fan and other objects, be
careful if you work on the fan or clean it.
8.
rates that are not delivered with the fan must be listed and
marked with the valve model that will be installed for use.
The switches must be general use switches UL. Take into
9.
staircase must be turned up and carefully push to the plug
box. The cables must be distributed in such a way that the
ground connected driver and the device head are next to
the socket.
necessary, followed.
WARNING: To reduce the risk of injury, blade brackets
cannot be folded during
Do not put any object on the path of blades.
WARNING:
Remove rubber motor
at the
of the fan before the blades or try
the motor.
WARNING: To avoid the risk of a fire or an
electrical blow, this fan should not be used with a
semiconductor speed controller.
WARNING: To avoid a possible electric shock,
turn off the current in the main security box
before wiring. If you feel that you do not have
enough knowledge or experience in electrical
wiring, communicate with a license electrician.
WARNING: Electrical diagrams only serve as a
be on the list and marked with this fan for use.
WARNING: To reduce the risk of fires, electrical
discharges or injuries, assemble the device in a
with a weight of £ 35) or less. It is marked and use
the screws supplied with the plug.
TECHNICAL INFORMATION
SKU
Nominal voltage
F6018CR
30W
24W 3000/4000/5000K, dimmable
Nominal output (motor) light
Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F6018CR
Make sure that there is a space of at least 30 cm between the
fan’s blades and any wall or other obstacle with which they
could collide.It is important to note that the greater the
distance,the more efficient the airflow would be.
0,3m
1
110-120V AC
F6018BK
24W 3000/4000/5000K, dimmable30W
F6018BK
110-120V AC

Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Remote control (1 PC)
4” Ball/downrod assembly and 10” downrod
Bolt “R” Lock Pin
Canopy
Canopy cover
Coupling cover
Plastic wire nut (3PCS)
Blade screw (16PCS)
Washer (16PCS)
5g
Balancing sticker (2PCS)
Balancing clip (1PC)
Mounting screw(2PCS)
Washer(2PCS)
Blade 5PCS
Fan-motor assembly
F6018CR
F6018BK
Light kit
1 2 4 8

1
Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
result in serious injury.
electrician install this fan.
screws & washers.
the blade to the nearest objects or walls.Secure
structure that is capable of carrying a load of at least 15.9kgs,with two long screws provided.
Ensure at least 30mm of the screws is threaded into the support.
Remove the bolt,”R” lock pin and 2 set screws from the downrod and then take down the hanger ball.
Insert the downrod into the coupling.
Gently push the bolt through the holes alighed with the base of the coupling and downrod.
Insert “R” lock pin into bolt and secure downrod with 2 set screws.
3
X15
X15
X5
X5
Install 5 blade brackets assembly to motor using the pre-installed screws. Tighten screws securely.
4
2
Remove 3 screws from the light kit, and then connect 2 connectors.
Install the light kit to the motor with 3 screws.
X2
x2
F6018CR
F6018BK
Bolt
2 set screws
“R” lock pin
coupling
X10
X10
X5
X3
X3

Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Aligh ball groove on hanger ball with ridge on hanger bracket.
has been secured into hanger bracket.
WARNING: Failure to aligh ball groove with ridge may result in serious injury.
ball groove
Ridge
5
OK
NO
FROM POWER SOURCE
AC 110- 120 VOLT 60Hz
3.5AMPS.
supplied with the
Use plastic wire nuts
fan
facing the ceiling.
WARNING: To avoid possible electrical shock, be sure electricity is turned off
at the main fuse box before wiring.
B
A
6
6
Slide the canopy up to ceiling and align the keyhole slots on the canopy with the 2 preassembled screws on the hanger bracket.
Clip the canopy cover in to secure it onto the canopy.
7
F6018CR
F6018BK
L
N
Ground wire
Black
White
Ground wire
MOTOR

Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Remote controller
GENERAL INFORMATION
1.INSTALLING RECEIVER IN CEILING FAN
A. Safety precautions:
electrical code requirements.
B. Electrical rating: 110/120V 50/60Hz
Electrical wire must meet all local and national
Otherwise power can cause serious injury or death.
F6018CR
F6018BK
FAN ON/OFF & Paring
- Within 5 seconds after power on,
hold press 3 seconds to match code
Forward and Reverse
- Press to change Forward/Reverse
- Within 5 seconds after power on,
hold press 3 seconds to clear code.
Light Switch & CCT Setting
- Press to turn light ON/OFF
- Hold press 2 seconds to change CCT
Timer Settings
- Press once, fan auto off after 1hr
- Press twice, fan auto off after 2hr
- Press 3 times, fan auto off after 4hr
- Press 4 times, fan auto off after 8hr
- Press 5 times,Cancel the timer function
LED Indicator
Time setting Indicator
Speed setting Indicator
Fan speed 1 to 6 levels
Fan speed 6 to 1 levels
1 2 4 8
Light brightness +
Light brightness -
2. OPE RATI NG TRAN SMITTER :
A. Instal l CR2032 3 volt ba ttery.
(To prev ent da mag e to tran smitter , remov e the batter y if not us ed for a long time).
B. Stor e the tran smitter away from exces sive he at or humidi ty.
C. Operat ing the bu ttons on the pa nel of the transmitter .
- Press to turn Fan ON/OFF

Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
6in
2.5in
4 or 10in
10.6 or 16.6in
9.4in
52in
16 or 22in
F6018CR
F6018BK

AFTER INSTALLATION
The fan blades have been adjusted in the factory to minimize any wobble
NOTE:CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY
ARE MOUNTED ON A RUBBER CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE
CEILING, IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMENTERS
IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM
WOBBLE”
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING
BRACKET AND DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
1.Check that all blade and blade arm screws are secure.
2.Mos
t fan wobbling problems are caused when blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of one of the
blades. Measure this distance.Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. The distance deviation should be equal within
1/8"(0.32cm).
3.If the blade wobble is still noticeable, interchanging two
adjacent (side by side) blades can redistribute the weight
and possibly result in smoother operation. WARNING: TO REDUCE THE RISK OF PERSONAL
INJURY, DO NOT BEND THE BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR
CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
NOISE
When it is quiet(especially at night) you may hear occasional small noises. This is normal. Please allow a 24-
hour “breaking-in” period, most noises associated with a new fan disappear during the time.
CARE AND CLEANING
1.Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to
avoid scratching the paint finish. Please make sure to turn off electricity power before you clean your fan
2.Do not use water when cleaning your ceiling fan. It could damage the motor or the blades
and create the possibility of an electrical shock.
3.Motor has permanently lubricated ball bearing. No need to oil
NOTE: MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU
ATTEMPT ANY CLEANING OR REPAIRS.
Installation & Operating Instructions for the
Parrot uncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F6018CR
F6018BK

Pot Uncle