Winix TOWER XQ Air Purifier

Product's Documents

Below are documents related to this product, you can read online or download:
TOWER XQ photo

User Manual

This is the main product document for model TOWER XQ. Additionally, the document applies to other Winix models: 1292967, 100474701

The file format is pdf, 22 pages, you can download this manual here .

background
User Manual
Model
Use & Care
Guide
ˍ
Please read and follow all safety rules and instructions in this
manual before operating.
ˍ
The product warranty is printed on the back of this guide, so
please keep it in a safe place for future use.
ˍ
This product is manufactured for use only in North America.
WINIX AIR PURIFIER
Tower XQ
background
2
Tower XQEnglish
CONTENTS
▶
This product is suitable for 120V only.
4-STAGE AIR PURIFICATION
·············································
3
CONTROLS
····························································
4
WHERE TO USE
························································
7
INSTALLING / REPLACING FILTERS
······································
8
FILTER CARE
··························································
10
SAFETY AND PRECAUTIONS
···········································
11
INITIAL OPERATION
···················································
12
CLEANING CARE
······················································
13
FREQUENTLY ASKED QUESTIONS
······································
17
UNIT SPECIFICATIONS
·················································
18
SAFETY INSTRUCTIONS
···············································
19
PRODUCT WARRANTY
················································
20
background
3
English Tower XQ
4-STAGE AIR PURIFICATION
Grill
Button Control Section
Display
Carbon Filter
Rear panel
Side vent
Pre-lter
Front panel
True HEPA lter
Air Quality Indicator (AQI)
User Manual
ㆍ
ㆍ
ㆍ
Please read and follow all safety rules and instructions
in this manual before operating.
The product warranty is printed on the back of this
guide, so please keep it in a safe place for future use.
This product is manufactured for use only in USA/CA
WINIX AIR PURIFIER
AM90
User Manual
Model
Use & Care
Guide
Unit (2) Pre-lter / (2) True HEPA Filter /
(2) Coated DeOdorization (CD)
Carbon Filters
background
4
English Tower XQ
CONTROLS
Grill
Air Quality
Indicator (AQI)
Display
Button Control
Section
Side vent
Display
Ultrafine
dust density
Indicator
Mode
Indicator
Timer
Indicator
Check Filter
Indicator
Plasmawave
Indicator
Wi-Fi
Indicator
Child Lock
Indicator
Sleep Mode
Indicator
Ultrafine Dust
background
5
English Tower XQ
Button Control Section
Power Button
Wi-Fi Button /
Device Pairing
Plasmawave®
Button
Sleep Mode /
Child Lock
Filter Life /
Filter Reset
Button
Fan Speed
Button
Timer
Button Description
Power Button
ˍ
Turns on/off the unit.
Fan Speed Adjustment Button
ˍ
Pressing the Fan Speed Adjustment Button will change the
unit's fan speed.
ˍ
Auto
→
Level 1
→
Level 2
→
Level 3
→
Turbo
→
Auto.
Timer Button
ˍ
A quick press of the timer Button will set the timer.
ˍ
The timer can be set, in hours, in the order of
0 (Default)
→
1
→
2
→
4
→
8
→
12
→
0.
ˍ
The amount of time, in hours, is indicated on the front
numeric display.
ˍ
Timer Indicator displays when timer is in use
PlasmaWave
®
Operation Button
ˍ
Turns on/off the PlasmaWave
®
feature.
CONTROLS
background
6
English Tower XQ
CONTROLS
Button Description
Sleep Mode / Child Lock Button
ˍ
A quick press of the Sleep Mode /Child Lock Button cycles
the unit in order from
Sleep Mode
→
General Mode
→
Sleep Mode.
ˍ
In Sleep Mode, the Sleep Mode LED Icon on the front indicator
dims to 50% brightness. All other LEDs are turned off.
ˍ
If you press Sleep Mode /Child Lock Button for 3seconds child
lock will be initiated and the buttons will not operate. and a
chime will sound if pressed.
Filter Life / Filter Reset Button
ˍ
A quick press will show the remaining filter life; indicated on
the front display (100 ~ 0%).
ˍ
A long press of 10seconds will reset the filter life indicator.
-
Use when replacing the filters
-
Filter Reset button can be used even after the power is
turned off.
-
The filter life will be reset to 100%.
Wi-Fi / Pairing
ˍ
A quick press will turn Wi-Fi on/off
ˍ
A long press of 3 seconds will activate pairing mode.
ˍ
A Wi-Fi indicator will display on the front while Wi-Fi is active.
background
7
English Tower XQ
WHERE TO USE
Allow 12 ~ 18 in. of space between TVs, radios, and other electronic products
Electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away from direct sun light
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
12~18 in 12~18 in
WARNING
Follow these instructions to reduce the risk of serious injury
or death and to reduce risk of damaging the unit.
Do not use around mist or fumes from
industrial oil or around large quantities of
metallic dust
Do not place around heating elements
Do not install in any sort of motor or
transport vehicle (trucks, boats, ships, etc.)
Do not place in an area with excessive
amounts of noxious gases
Do not place near any flammable
materials (aerosols, fuel, gases etc.)
Do not have unit facing into wind or draft
Do not place below any electrical outlet
Do not place in excessively humid areas
where unit may become wet
•
This unit is not intended to be used to preserve documents or in art conservation.
background
8
English Tower XQ
This product comes with all the required filters. The protective plastic wrap must be
removed from the filters before use.
•
Operating the unit without removing the plastic wrap may result in product failure.
•
Unplug and make sure the unit is turned off before installing filters.
①
Remove the front/rear panel by grasping
its upper edge and gently pulling forward.
ˍ
To remove the front/rear panel release
the latch at the lower edge of the panel.
Latch
②
Press the Pre-filter tabs near the top of
the filter, release and remove.
③
If replacing the filters pull out the used (CD)
Carbon Filter and True HEPA filter.
INSTALLING / REPLACING FILTERS
background
9
English Tower XQ
INSTALLING / REPLACING FILTERS
④
Remove the new filters from protective
plastic wrap.
ˍ
Operating the unit without removing
filters from plastic wrap may cause
abnormal noise, deformation or fire as a
result of overheating.
⑤
Install the new filters until they fit securely
in place.
Filters must be installed in this order:
3 True HEPA filter (rear)
2 (CD) Carbon filter (middle)
1 Pre-filter (front)
ˍ
To install the Pre-filter, insert bottom tabs
into the slots on either side of the lower part
of the unit, then rotate upward to insert the
upper tabs into the slots at the top part of
the unit until sides audibly click into place.
⑥
Replace the front panel by first inserting
the latch at the bottom edge into the base
of the unit, then rotate the panel upward
toward the top of the unit until the magnets
pull the lid closed.
Latch
⑦
Resetting the Unit
ˍ
After replacing the filters, turn the power
onto the unit and then press and hold the
Filter Reset Button for 10 seconds.
background
10
English Tower XQ
Filter Indicator Light
When to
service
When to replace
1 Pre-filter
none
Clean once every
14days
Permanent
2 Coated DeOdorization
(CD) Carbon filter
Can NOT be
WASHED
Replace every
12 months
3 True HEPA filter
Lasts up to
12 months
Filter Care
•
Intervals between filter replacement may vary depending on environment.
•
For optimal use, Pre-filter can be cleaned once every 14 days which can extend the
life of other filters.
To purchase replacement
Winix filters:
(877)-699-4649
www.winixamerica.com
NOTE
ˍ
The filters’ life varies depending on the level of pollutants in
the air. The more dust present in the environment, the more
dust accumulates in the filters, shortening the life.
ˍ
If the filters are heavily soiled or have a bad odor, or if the fan
strength is significantly weakened, replace filters even if the
Change Filter indicator has not yet turned on.
NOTICE
ˍ
For optimal performance, only Winix filters should be used
with this unit.
background
11
English Tower XQ
SAFETY AND PRECAUTIONS
Before operating this equipment, carefully read and follow these safety cautions
Ensure filters are inserted before running unit.
Running unit without filters can shorten the units life and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit.
Objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands.
The high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked.
Blockage may lead to increased internal termperatures causing product failure and derformation.
Do not use the unit as a step stool or place heavy objects on it.
Personal injury may occur or product failure and deformation.
WARNING
Follow these instructions to reduce the risk of serious
injury or death and to reduce risk of damaging the unit.
Do not pull on the power cord when
unplugging the unit
Do not tie or knot power cord when unit
is in operation
If the unit becomes submerged in water,
unplug it and contact customer service
Do not unplug or move the unit while in
operation
Unplug unit when not in operation for
extended periods of time
Do not touch the plug with wet hands
Cord can become damaged by forcefully
bending, pulling, twisting, bundling,
pinching or placing heavy objects on it
background
12
English Tower XQ
INITIAL OPERATION
①
Insert the power cord into an electrical
outlet.
②
Press the ‘Power’ button.
NOTE
ˍ
During the first 4 minutes of power up, the Air Quality
Indicator will flash as the Smart Sensors measure the air
quality in the environment, after which normal operation will
begin.
③
By default, when the unit first powers on, the
mode will be set to Auto with PlasmaWave
®
enabled.
ˍ
When in Auto mode, the fan speed will
be automatically adjusted according to
the environments air quality.
ˍ
PlasmaWave
®
works to remove harmful
airborne contaminants.
NOTE
ˍ
In Auto mode, as the indoor air quality improves, the fan
speed will automatically be reduced to Low.
ˍ
When the unit is running, you may hear a chirping or buzzing
sound. The sound is from large particles passing through
PlasmaWave
®
, it is normal and does not signify product
failure. To disable PlasmaWave
®
, see page 5.
background
13
English Tower XQ
CLEANING CARE
1. Cleaning the Exterior & Interior
①
Wipe with a soft damp cloth using room
temperature water. Afterwards, wipe down
with a clean dry cloth.
ˍ
To keep unit in peak condition, clean
every 1-2 months.
②
Open the front panel and clean the interior
with a hand vacuum.
ˍ
For optimal performance, clean every
1-2 months.
NOTICE
ˍ
When cleaning the unit, always unplug the power cord first
and then wait until the unit has cooled down.
ˍ
Never disassemble, repair, or modify this unit yourself.
ˍ
Do not use flammable sprays or liquid detergents on or near
the unit. .
ˍ
Do not allow children to clean or maintain the unit.
ˍ
Before cleaning or maintaining, ensure unit is unplugged.
background
14
English Tower XQ
CLEANING CARE
2. Cleaning the Top
①
Grasp the back of the grill and lift it up.
②
Wipe the interior and grill with a soft damp
cloth.
③
To reinstall the grill insert the two front tabs
of the grill into the corresponding holes in
the product.
background
15
English Tower XQ
CLEANING CARE
3. Cleaning the Pre-Filter
Intervals between pre-filter cleaning may vary depending on the air quality.
①
Use a handheld vacuum or soft brush to
clean the pre-filter. If it is excessively dirty,
rinse in room temperature water.
ˍ
Do not use detergent or soap.
ˍ
Allow the filter to fully dry before using.
•
If the pre-filter becomes damaged or in any way needs replacement:
Please contact Winix
Call: (877)-699-4649
Visit: www.winixamerica.com
NOTICE
ˍ
Do not use benzene, alcohol, or other volatile fluids, which
may cause damage or discoloration.
ˍ
The Pre-filter is reusable after cleaning, ensuring it is
completely dry.
ˍ
Allow it to dry completely in a well ventilated area.
Otherwise, it may develop a bad odor.
ˍ
Do not use hot water over 104
o
F or volatile fluids such as
paint thinner.
background
16
English Tower XQ
CLEANING CARE
4. Cleaning the Particle Sensor
①
Open the Particle Sensor cover on the back
of the unit.
②
Use a damp cotton swab to wipe the lens
and intake area of the Particle sensor.
ˍ
To clean the sensor area, use only water.
ˍ
Do not use volatile substances such as
alcohol or acetone.
Lens
Cotton
swab
Lens
③
Wipe away any remaining moisture with a
dry cotton swab.
④
Close the Particle Sensor cover.
ˍ
The Particle Sensors cover may be
cleaned using a handheld vacuum.
background
17
English Tower XQ
FREQUENTLY ASKED QUESTIONS
Problem Check / Actions to take
The unit does not
turn on at all.
ˍ
Is the plug securely attached to the outlet?
-
Make sure the outlet has power going to it, and
ensure the plug is secured.
ˍ
Is there a power outage?
-
Check to see if other lights and electrical
equipment are working and try again.
The unit doesn’t
work in Auto
Mode.
ˍ
Has Auto Mode been selected?
-
Press the Mode button until Auto Mode is
selected.
ˍ
Is the sensor blocked or clogged?
-
Wipe Odor Sensor with a wet cloth, then dry.
The unit vibrates
and makes a lot of
noise.
ˍ
Is it running on a slanted or uneven surface?
-
Move the unit to a hard, flat, even area of the
floor.
The unit power
plug and outlet
feel hot.
ˍ
Is the plug securely plugged in?
-
Make sure the plug is properly plugged into the
outlet.
There is a strange
smell.
ˍ
Is the unit being used in a place with a lot of smoke,
dust, or odors?
-
Clean the air intakes on either side and clean
the pre-filter.
-
Replace the Carbon filter and True HEPA filter.
The fan strength
is weak.
The unit is not
purifying the air.
ˍ
Is the Check Filter indicator light on?
-
Change the filters as required.
The display panel
is dim/off.
ˍ
Is sleep mode on?
-
Check the display and press the Sleep Mode
button to cycle Sleep Mode on/off.
ˍ
Is the Light Sensor blocked by debris?
-
When Auto Mode is on, Sleep Mode is
automatically activated when the Light Sensor
detects that the room is dark.
background
18
English Tower XQ
UNIT SPECIFICATIONS
Model Name Tower XQ
Power Voltage
AC 120 V / 60 Hz
Power Rate 90W
Room Area Served 628 ft
2
Dimensions
14.6 in(W) x 14.6 in(D) x 31.3 in(H)
Weight 30.86 lbs
•
The exterior, design and product specifications may be changed without
prior notice to improve product performance.
•
Information regarding ENERGY EFFICIENCY RATING LABEL
The energy costs indicated on the ENERGY EFFICIENCY RATING LABEL may differ
from your actual energy costs, depending on your energy consumption, usage
hours, and billing changes, such as utility price increases.
Warning : Change or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Note : This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures.
ˍ
Reorient or relocate the receiving antenna.
ˍ
Increase the separation between the equipment and receiver.
ˍ
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
ˍ
Consult the dealer or on experienced radio/TV technician for help.
This device complies with Industry Canada's license-exempt RSSs. Operation is subject to the
following two conditions:
ˍ
This device may not cause interference and
ˍ
This device must accept any interference, including interference that may cause undesired
operation of the device.
background
19
English Tower XQ
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air purifier. This product is for indoor use only.
WARNING : Follow the instructions in this
manual to reduce the risk of electric shock,
short circuit, and/or fire.
ˍ
Do not repair or modify the unit unless
specifically recommended in this manual.
All other repairs should be completed by a
qualified technician.
ˍ
The plug for this unit is polarized with one
blade wider than the other. Do not force
the plug into an electrical outlet. Do not
alter the plug in any way. If the does not fit
into the outlet, reverse the plug.
If it still does not fit, contact a qualified
technician to install a proper outlet.
ˍ
Do not use if the power cord or plug is
damaged or the connection to the wall
outlet is loose.
ˍ
Use AC 120V only.
ˍ
Do not damage, break, forcefully bend, pull,
twist, bundle, coat, pinch, or place heavy
objects on the power cord.
ˍ
Periodically remove dust from the power
plug. This will reduce the risk of shock due
to humidity build up.
ˍ
If the power plug is damaged, it must be
replaced by the manufacturer or a qualified
technician.
ˍ
Remove the power plug from the outlet
before cleaning the unit. When removing
the power plug, grasp by holding the plug
itself, never hold by the cord.
ˍ
Remove the power plug from the outlet
when not in use.
ˍ
Do not handle the power plug with wet
hands.
ˍ
Do not operate the unit when using indoor
smoke-generating insecticides.
ˍ
Do not clean unit with benzene or paint
thinner. Do not spray insecticides on the unit.
ˍ
Do no
t use the unit where it is humid or
where the unit may become wet, such as
the bathroom.
ˍ
Do not insert fingers or foreign objects into
air intake or outlet.
ˍ
Do not use the unit near flammable gases.
Do not use near cigarettes, incense, or
other spark-creating items.
ˍ
Unit will not remove carbon monoxide
emitted from heating appliances or other
sources.
ˍ
Do not block the intake or outlet vents.
ˍ
Do not use near hot objects, such as a
stove.
ˍ
Do not use where the unit may come into
contact with steam.
ˍ
Do not use the unit on its side.
ˍ
Keep away from products that generate
oily residue, such as a deep fryer.
ˍ
Do not use detergent to clean the unit.
ˍ
Do not operate without a filter.
ˍ
Do not wash and reuse the True HEPA Filter
or the CD Carbon Filter.
ˍ
Hold the handle on the back of the unit to
transport.
ˍ
Do not hold by the front panel.
IMPORTANT PRECAUTIONS FOR USING YOUR AIR PURIFIER
background
20
English Tower XQ
The terms of the warranty are as follows.
1
This product is manufactured under stringent quality control and inspections.
2
Warranty void if product failure is a result of negligence or misuse by the consumer,
shipping. Service fees may be incurred even during the warranty period.
3
The warranty must be presented upon bringing the product for service.
4
Store the warranty in a safe place, as it cannot be reissued.
5
This warranty is valid only in the USA and Canada.
Product Name
Air Purifier
Model Name
Tower XQ
Purchase Date
Warranty period
Two (2) years
Place of purchase
Place of purchase Tel.
Customer
Address
Name
Tel.
•
After purchase, be sure to complete all of the above information.
PRODUCT WARRANTY
background
21
English Tower XQ
MEMO
background
Contact for product
related inquiries and
customer service
To expedite service, please specify the model name and number, the
nature of the problem, your contact information, and your address.
●
Dedicated Call Center : (877) 699-4649
●
Website : www.winixamerica.com
0000-0000-00 Rev.00

Specifications

Indexed Terms: Air Purifier, Tower

Winix TOWER XQ Questions and Answers

Questions and Answers

Related Products

Product Winix 5520 image
Winix 5520 Air Purifier
2025-09-05 1 docs