ZK-D1090 User Manual
Contents 1
User Manual
Walk Through Metal Detector
ZK-D1090
Date: July 2025
Doc Version: 1.0
English
Thank you for choosing our product. Please read the instructions
carefully before operation. Follow these instructions to ensure that the
product is functioning properly. The images shown in this manual are for
illustrative purposes only.
For further details, please visit our Company’s website
www.zkteco.com
.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 1
Copyright © 2025 ZKTECO CO., LTD. All rights reserved.
Without the prior written consent of ZKTeco, no portion of this manual can be
copied or forwarded in any way or form. All parts of this manual belong to ZKTeco
and its subsidiaries (hereinafter the "Company" or "ZKTeco").
Trademark
is a registered trademark of ZKTeco. Other trademarks involved in this
manual are owned by their respective owners.
Disclaimer
This manual contains information on the operation and maintenance of the ZKTeco
equipment. The copyright in all the documents, drawings, etc. in relation to the
ZKTeco supplied equipment vests in and is the property of ZKTeco. The contents
hereof should not be used or shared by the receiver with any third party without
express written permission of ZKTeco.
The contents of this manual must be read as a whole before starting the operation
and maintenance of the supplied equipment. If any of the content(s) of the manual
seems unclear or incomplete, please contact ZKTeco before starting the operation
and maintenance of the said equipment.
It is an essential pre-requisite for the satisfactory operation and maintenance that
the operating and maintenance personnel are fully familiar with the design and
that the said personnel have received thorough training in operating and
maintaining the machine/unit/equipment. It is further essential for the safe
operation of the machine/unit/equipment that personnel has read, understood and
followed the safety instructions contained in the manual.
In case of any conflict between terms and conditions of this manual and the
contract specifications, drawings, instruction sheets or any other contract-related

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 2
documents, the contract conditions/documents shall prevail. The contract specific
conditions/documents shall apply in priority.
ZKTeco offers no warranty, guarantee or representation regarding the
completeness of any information contained in this manual or any of the
amendments made thereto. ZKTeco does not extend the warranty of any kind,
including, without limitation, any warranty of design, merchantability or fitness for
a particular purpose.
ZKTeco does not assume responsibility for any errors or omissions in the
information or documents which are referenced by or linked to this manual. The
entire risk as to the results and performance obtained from using the information is
assumed by the user.
ZKTeco in no event shall be liable to the user or any third party for any incidental,
consequential, indirect, special, or exemplary damages, including, without
limitation, loss of business, loss of profits, business interruption, loss of business
information or any pecuniary loss, arising out of, in connection with, or relating to
the use of the information contained in or referenced by this manual, even if
ZKTeco has been advised of the possibility of such damages.
This manual and the information contained therein may include technical, other
inaccuracies or typographical errors. ZKTeco periodically changes the information
herein which will be incorporated into new additions/amendments to the manual.
ZKTeco reserves the right to add, delete, amend or modify the information
contained in the manual from time to time in the form of circulars, letters, notes, etc.
for better operation and safety of the machine/unit/equipment. The said additions
or amendments are meant for improvement /better operations of the
machine/unit/equipment and such amendments shall not give any right to claim
any compensation or damages under any circumstances.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 3
ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment
malfunctions due to any non-compliance of the instructions contained in this
manual (ii) in case of operation of the machine/unit/equipment beyond the rate
limits (iii) in case of operation of the machine and equipment in conditions different
from the prescribed conditions of the manual.
The product will be updated from time to time without prior notice. The latest
operation procedures and relevant documents are available on
http://www.zkteco.com
If there is any issue related to the product, please contact us.
ZKTeco Headquarters
Address ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone +86 769 - 82109991
Fax +86 755 - 89602394
For business-related queries, please write to us at sales@zkteco.com
.
To know more about our global branches, visit www.zkteco.com.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 4
About the Company
ZKTeco is one of the world’s largest manufacturer of RFID and Biometric
(Fingerprint, Facial, Finger-vein) readers. Product offerings include Access Control
readers and panels, Near & Far-range Facial Recognition Cameras, Elevator/floor
access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and
Consumer products including battery-operated fingerprint and face-reader Door
Locks. Our security solutions are multi-lingual and localized in over 18 different
languages. At the ZKTeco state-of-the-art 700,000 square foot ISO9001-certified
manufacturing facility, we control manufacturing, product design, component
assembly, and logistics/shipping, all under one roof.
The founders of ZKTeco have been determined for independent research and
development of biometric verification procedures and the productization of
biometric verification SDK, which was initially widely applied in PC security and
identity authentication fields. With the continuous enhancement of the
development and plenty of market applications, the team has gradually
constructed an identity authentication ecosystem and smart security ecosystem,
which are based on biometric verification techniques. With years of experience in
the industrialization of biometric verifications, ZKTeco was officially established in
2007 and now has been one of the globally leading enterprises in the biometric
verification industry owning various patents and being selected as the National
High-tech Enterprise for 6 consecutive years. Its products are protected by
intellectual property rights.
About the Manual
This manual introduces the operations of the ZK-D1090 Walk-through Metal
Detector.
All figures displayed are for illustration purposes only. Figures in this manual may
not be exactly consistent with the actual products.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 5
Table of Contents
1 OVERVIEW ....................................................................................................... 7
1.1 Introduction ....................................................................................................... 7
1.2 Appearance ........................................................................................................ 8
1.3 Components ....................................................................................................... 9
2 PRODUCT SPECIFICATIONS .......................................................................... 10
2.1 Dimensions .......................................................................................................10
2.2 Technical Specifications .................................................................................11
3 INSTALLATION SETUP ................................................................................... 13
3.1 Safety Precautions ..........................................................................................13
3.2 Instructions to Pedestrians ............................................................................13
3.3 Installation Site ................................................................................................14
3.3.1 Stationary Metallic Items ................................................................................................................. 14
3.3.2 Portable Metallic Items ..................................................................................................................... 14
3.3.3 Floor Vibration......................................................................................................................................... 14
3.3.4 Electromagnetic Radiation and Interference .................................................................... 14
3.3.5 Parallel Installation ............................................................................................................................... 15
3.4 Installation Steps .............................................................................................15
4 PERFORMANCE AND TECHNICAL FEATURES ............................................... 17
5 CONTROL PANEL ........................................................................................... 18
6 DETECTION ZONES ........................................................................................ 19

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 6
6.1 Adjustment of Detection Zone’s Sensitivity ...............................................20
7 OPERATIONAL PROCEDURE.......................................................................... 21
7.1 Sensitivity Adjustment ...................................................................................22
7.2 Channel Settings .............................................................................................23
7.3 Alarm Settings .................................................................................................24
7.4 Application Area ..............................................................................................25
7.5 Random Alarm .................................................................................................26
7.6 Record ...............................................................................................................27
7.7 System ...............................................................................................................29
7.8 About .................................................................................................................30
7.9 Default Parameters .........................................................................................31
TROUBLESHOOTING ............................................................................................. 32
PACKING LIST......................................................................................................... 33
WARRANTY CARD .................................................................................................. 34

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 7
1 Overview
1.1 Introduction
ZK-D1090 metal-detector is a walk-through metal-detector that is used for security
screening at access points in the prisons, courthouses, and train stations.
Metal-detectors are highly sensitive to magnetic metals and have a high detection
capability, with less ability to detect non-magnetic metals. They are used to detect
the concealed metal weapons on a person’s body. It offers high-speed detection
capability. It can detect large metal objects like knives and guns. Its screening
capacity is very large when compared to hand-held metal detectors.
Feature
Up to 9 detection zones and 500 sensitivity levels allow precise contraband
detection.
Accurate detection of a wide range of contrabands.
Clear threat indication with synchronous sound alert and LED indicator.
Displays the number of pedestrians passed and alarm count accurately.
Automatic setting of sensitivity and channel.
Simple installation and use.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 8
1.2 Appearance

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 9
1.3 Components
1. Beam 2. LED Alarm Zones 3. Built-in Probe
4. Infrared Sensors 5. Foot Cover 6. Power-line Interface

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 10
2 Product Specifications
2.1 Dimensions

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 11
2.2 Technical Specifications
Display 2.8'' TFT Color Screen
Physical Keypad 4 keys
Detection Zone 3/6/9 zones mode adjustable
Sensitivity Level 500
Channel 100
Smallest Metal Objects
Detected
Coin-sized Metals
22.25*T1.85 mm (Steel-nickel Alloy)
Maximum Detection
Distance
Vertical 20-2000mm
Detection Sound Alert
6 types of alarm tones (adjustable)
0-6 levels of volume adjustable (Maximum volume 80
dB)
Detection Visual Indicator
2 sets of LEDs (red) are evenly distributed on the left a
nd right door panels
LED (Steady red= metal contraband detected)
Throughput > 40 persons per minute
Self-diagnosis Program Yes
Detection Mode
Automatic Detection Mode/ Infrared Detection Mode
(default)
Number of IR Groups 1

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 12
Detected Contraband Ferrous and non-ferrous metal weapons
Enclosure Material
Flame Retardant ABS Polymer, Medium Density Fiberb
oard, PVC
Power supply AC100V to 240V (DC12V/3A)
Input Voltage DC12V
Operating Current 0.8A
Operating Power 10W
Operating Time (Estimated) 24/7 operation capability (continuous operation)
Operating Frequency 5.7KHz ~ 9.6KHz
Operating temperature -10°C ~ 45°C
Storage Temperature -20°C ~ 55°C
Operating Humidity <95% RH (non-condensing)
Application Environment Indoor
Dimensions (L*W*H) 2221 * 859 * 405 (mm)
Lane Size (L*W*H) 2007 * 710 * 315 (mm)
Dimensions with Packaging
(L*W*H)
2280 * 457 * 280 (mm)
Weight
Gross Weight: 34kg
Net Weight: 30kg
Certifications CE, FCC, ISO9001

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 13
3 Installation Setup
3.1 Safety Precautions
• Install the detector in a stable and smooth area. Make sure that the
detector is installed firmly in the selected area.
• It can be used for both indoor and outdoor purposes. If used outdoor,
cover it with a canopy to protect against rain.
• Before installation, make sure the left and right door panels are placed at
the corresponding location. Avoid high temperatures and wet
environments.
• Wait for 1 minute for the self-diagnosis of the detector when it starts. Do
not touch the detector during a security check to avoid false alarm.
• Install the detector away from radio-frequency devices to avoid
interference. Make sure that there is no large metal object or strong
magnetic field around the detector for at least 2 meters.
• Do not hit the detector hardly, as it may cause false alarms.
• Do not disassemble the unit without the guidance of a professional
technician.
• Each device has a warranty card, with which users can have their devices
maintained or repaired free of charge within the warranty period.
3.2 Instructions to Pedestrians
• A line must be drawn at 50cm away from the detector. The pedestrians
must pass through the detector one-by-one.
• Pedestrians should line up one-by-one to ensure the smooth operation of
the detector.
• Pedestrians should walk at a normal speed. They must not intentionally
form a crowd, rush, walk slowly, or crush the door panel.
• Before passing through the metal detector, the pedestrians must remove
all the carried metal objects (such as keys, mobile phone, watch, coins, etc.),

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 14
and place it on the security chute or a table, and pick it up after the security
check.
• If the detector alarms when someone passes through, that means there
is/are some metal object(s) hidden in the body. The security guard can use
a hand-held metal detector to accurately detect the hidden position
according to the alarm zones.
3.3 Installation Site
The following section describes the requirements of the installation environment.
3.3.1 Stationary Metallic Items
The detector must be installed away at 50cm from the stationary metallic items
such as aluminum alloy/stainless-steel windows, doors, etc. to prevent false alarms
and affecting the sensitivity of the detector.
3.3.2 Portable Metallic Items
The portable metallic objects must be kept away at 2 meters from the detector to
avoid false alarms.
3.3.3 Floor Vibration
The installation floor must be flat and fixed to avoid false alarm from the movement
of the people walking through the detector.
3.3.4 Electromagnetic Radiation and Interference
Since the detector uses Bilateral receiver technology, the detector must be installed
away at a distance of at least 1 meter from the sources of electromagnetic radiation
or electromagnetic interference. The parameters that define the distance are
determined by the installation environment and the parameters vary for different
installation environments.
The sources of electromagnetic radiation and electromagnetic interference are
given below:

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 15
Electrical Control Box, Radiofrequency equipment, Interphone, High Power Motor,
Power Transformer, Ac Power Lines, Thyristor Control Circuit (High Power Switching
Power Supply, Inverter Welder), Engine, Motor, etc.
3.3.5 Parallel Installation
When two detectors are installed parallel to each other, the distance between two
detectors must be greater than 50cm. When three detectors are installed parallel to
each other, the distance between each detector must be greater than 80cm. They
must operate at a different frequency to avoid interference. The distance varies
according to the actual working environment, it is not recommended to mount
three detectors in parallel, the frequency can be adjusted according to the
environment.
3.4 Installation Steps
Make sure that the device is installed as per the following installation instructions. If
you want to open the chassis, you should contact the agent for permission.
Otherwise, you will bear any consequence resulting from your actions.
Left Door Panel
Right Door Panel

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 16
1. Open the Control unit and Door panel package.
2. Install the control unit and the door panels as shown in the above diagram.
Connect the door panels to the control unit with bolts and nuts and tighten the
screws.
3. Insert the probe-lines of the left and right door panels to the corresponding
sockets on the mainboard.
4. Then lift the Walk-through metal detector vertically and place it in the required
area.
5. Finally, plug in the power cable to start working.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 17
4 Performance and Technical Features
Accurate Positioning: There are 9 overlapping detection zones with bilateral
transmit and receive technology. The detection zones can accurately detect the
objects with an intuitive display of the target location.
Adjustable Sensitivity: The detection zones have 500 sensitivity levels (0 to 500).
You can preset the metal size, by excluding the false alarm of coins, keys, jewelry,
belt buckle, etc.
Digital Pulse Technology: Digital signal processing and filtering system in the
detector has excellent anti-interference ability.
Count Statistics: The detector displays the number of pedestrians passed and Alarm
count accurately.
Harmless: The detector is harmless to heart pacemakers, pregnant women,
magnetic floppy disks, recording tapes, etc.
Easy to install: The detector has an integrated design and it can be effortlessly
installed or disassembled in 15 minutes.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 18
5 Control Panel
The components of the Control Panel are given below:
1. LCD: Displays the Pass count, Alarm count, Password settings, and other
information.
2. ESC: Press to discard the settings and exit the menu.
3. ▽: Adjustment (decrement) key to decrease the parameter values.
4. △: Adjustment (increment) key to increase the parameter values.
5. OK: Opens the Menu interface, saves the settings, and exits the menu.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 19
6 Detection Zones
The detector can detect a wide range of threat objects/weapons composed of
magnetic, non-magnetic metals and alloys.
Chassis Panel: The screen shows the number of people passing the detector and
the number of alarms.
Alarm Zones:
3-zone Mode 6-zone Mode 9-zone Mode
There are two unique sets of precise positioning LEDs evenly distributed on the
door panels. If the detected metal object reaches or exceeds the preset value, the
red LED glows and an alarm will be triggered. If there are multiple alarm targets, the
LED of each target location will glow with alarm.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 20
Infrared Sensor
After connecting the power supply, the metal detector starts to work. When there is
no person or object passes through the detector, the infrared sensors can
effectively stop alarming to avoid false alarms. It also helps to maintain an accurate
count of pedestrians and alarms.
6.1 Adjustment of Detection Zone’s Sensitivity
1. The device must be in a stable position to achieve the best detection effect
(refer Installation Site
). To check whether the device is in a stable state,
perform the following steps:
a) Power on the detector and check whether it is not shaking after one
minute.
b) The device should not alarm when the testing person did not carry any
metal items while walking through the detector.
2. You can exclude the small portable metal objects such as rings, key, belt
buckle, shoes, and so on, by following the steps given below:
a) Choose a small metal as a sample. Increase the sensitivity, so that when
the testing person carries the sample and pass through the detector, and
it would alarm.
b) Decrease the sensitivity a little, carry the sample, and pass through the
detector again. If it still alarms, once again reduce the sensitivity, until the
device does not alarm when the sample is passed through.
Note: If you want to decrease the sensitivity in a certain zone, you must only adjust
the sensitivity of the relative zone. After implementing the above adjustments, the
metal smaller than the sample will not alarm, but the metal objects bigger than the
sample can be detected accurately.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 21
7 Operational Procedure
Connect the power supply to the detector. After 2 seconds of initialization, the
following standby interface is displayed.
CH:57 Normal 14:16
PASS
00454
ALARM
00436
The standby interface displays the following content: Working Channel, Time, Pass
count, and Alarm Count.
Press the OK button on the Control panel and enter the login password
(default:100000) to enter the main menu.
Login
Password
* * * * * *
MENU
Sensitivity
Channel
Alarm
Application
RandomAlarm

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 22
7.1 Sensitivity Adjustment
On the main menu, select Sensitivity to enter the Sensitivity interface.
Sensitivity
Manual Setting
Auto Setting
Sens Range
Select Manual Setting and press OK to set the sensitivity level of each detection
zone. Press “
▽” and “△” to select the detection zone and then press OK to confirm.
Then press “
▽” and “△” to change the sensitivity values. The larger the sensitivity
value, the higher the sensitivity. Then press OK to save the settings.
Sensitivity
Overall: 186
ZoneALL
:
469
Zone 6
:
469
Zone 5
:
469
Zone 4
:
469
Zone 3
:
469
Zone 2
:
469
Zone 1
:
469
Note: 7-9 are Virtual zones, which can't be shown in the zone setting as those zone
settings are by defult.
Record
System
About

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 23
Select Auto Setting and press OK to set the sensitivity automatically. It will be set
up in a few seconds.
Select Sens Range and then press OK to set the intensity of the sensitivity levels.
Press “
△” and “▽” to select the sensitivity settings for all the zones. Press OK to save
the settings.
Sens Range
High
Medium
Low
7.2 Channel Settings
In the main menu, select Channel to enter the Channel interface.
Channel
Manual Setting
Auto Setting
Select Manual Setting and then press OK. The channel range is from 1 to 100. The
default value is 57. Press “
△” and “▽” to set the value and then press OK to save
the settings.
Channel
001——100
Select Auto Setting and press OK to set the channel automatically. It will be set up
in a few seconds.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 24
7.3 Alarm Settings
In the main menu, select Alarm to enter the Alarm interface.
Alarm
Buzzer
Alarm Time
Tone
Volume
Select Buzzer and then press OK to confirm. Press “△” and “▽” to select whether
to turn on or off the buzzer and press OK to save the settings.
Buzzer
OFF
ON
Select Alarm Time and then press OK to confirm. The default alarm time is 1 second.
Press “
▽” and “△” to select the alarm time as per your requirements and press OK to
save the settings.
Alarm
0.5s
1.0s
1.5s
2.0s
…
10.0s
Select Tone and then press OK to confirm. Press “▽” and “△” to select the tone and

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 25
press OK to save the settings.
Tone
1
2
3
4
5
6
Select Volume and then press OK to confirm. Press “▽” a nd “△” to set the alarm
volume and press OK to save the settings.
Volume
1
2
3
4
5
6
7.4 Application Area
In the main menu, select Application and then press OK to confirm. Press “△” and
“
▽” to adjust the real-time application area. Press OK after setting the application
area. (There are a total of 72 applications to choose from.)

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 26
Application
Airport
Customs
Port
Prison
Detention
Police Office
Train Station
…
Cartridge Industry
7.5 Random Alarm
In the main menu, select RandomAlarm to enter the random alarm setting
interface.
Random
Setting
Tone
Select Setting and then press OK to confirm. Press “▽” and “△” to set the value and
press OK to save the settings.
Under normal circumstances, the alarm is generated when the amount of metal
signal reaches the set sensitivity threshold, while it can pass normally when it is less
than the threshold. When a random alarm value is set, there will be a n% probability
that a normal pass without alarm will be turned into an alarm, so that it can be
checked and confirmed again manually.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 27
Random Alarm
00——50%
Select Tone and then press OK to confirm. Press “▽” and “△” to select the tone and
press OK to save the settings.
Tone
1
2
3
4
5
6
7.6 Record
In the main menu, select Record to enter the Record interface.
Record
Record Query
Storage
Select Record Query and then press OK to confirm. Press “▽” a nd “△” to set the
start time and end time and press OK to search the corresponding records.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 28
Start Time
2025-06-19
00:00
End Time
2025-06-19
23:59
Record Query
Pass:783
ALARM:744
2025-06-19 09:29:09
2025-06-19 09:29:09
2025-06-19 09:50:51
2025-06-19 09:50:51
2025-06-19 09:51:13
Select Storage and then press OK to confirm. Press “▽” and “△” to select whether to
save the data or not. You can also delete the pedestrian count and Alarm count.
Press the OK to save the settings.
Storage
Save
Don’t Save
Clear Pass (Clear Pedestrian Count)
Clear Alarm (Clear Alarm Count)

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 29
7.7 System
In the main menu, select System to enter the system setting interface.
System
Date & Time
Work Mode
Password
Restore
Select Date & Time and then press OK to confirm. Press “△” and “▽” to adjust the
time then press OK to save the changes.
Date & Time
2025-06-19
15:26
Select Work Mode and then press OK to confirm. Press “△” and “▽” to select the
zone mode then press OK to save the changes.
WorkMode
Zone 3
Zone 6
Zone 9
Select Password and then press OK to confirm. Press “△” and “▽” to set the
password, and press ESC to clear the entered value. Press OK to save the settings.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 30
Password
New Password
* * * * * *
Select Restore and then press OK to confirm. Press “△” and “▽” to choose whether
to restore factory settings. Select " Ye s" and press OK to restore the original factory
settings. Select "Cancel" or press ESC to cancel the operation.
Restore
Cancel
Yes
7.8 About
Show firmware version number.
About
Ver:
EN-09-N-1.0.0

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 31
7.9 Default Parameters
Parameter
Default Value
Sensitivity
Overall: 186
ZK-D1090: 469
Channel
57
Buzzer
ON
Alarm Time
1.0 s
Application Area
Train Station
Data Saving
Save
System Password
100000

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 32
Troubleshooting
What to do if the Sensor could not count?
a) Check whether the probe cables are connected firmly with the door panels.
b) Check whether there is any infrared interference beside the device, such as
infrared surveillance system, infrared remote control, outdoor sunlight, etc.
c) If both a and b are OK, replace the infrared sensor.
What to do if the detector gives a false alarm?
a) If the device gives false alarms frequently after installation, perform the
following steps:
• Firstly, check the installation environment. Make sure there are no movable
or stationary large metal objects around 1.5 meters from the detector. If
there is any metal object, try to place the device away from the large metal
objects.
• Make sure that the installation location is stable and free from physical
movements.
b) If the false alarm is not caused by the environment, reduce the sensitivity level
of all zones.
c) Change the frequency.
d) Change the installation location.

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 33
Packing List
The package consists of the following items:
No Component Quantity
1
Power Adapter 1 set
2
Power Cable 1 set
3
Hexagon Socket Set Screw 8 pcs
4
Inner Hexagon 1 pc
5
User Manual 1 pc
6
Beam 1 set
7
Panel 2 sets

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 34
Warranty Card
1. Please keep this card safe and produce the same during maintenance.
2. This card will be invalid without the signature or stamp of the designated
dealer.
3. This card will be regarded as invalid if the details are not filled in three
guarantees column and the acknowledgment of the receipt. Please confirm
whether the data filled in the three guarantees column and acknowledgment
of receipt is correct or not when purchasing it, and then hand it over to the
dealer.
4. This card will not be issued again if it is lost.
Model Number
ID
Date of Acquisition
User
Post Code
Address
User’s Phone Number
Fax

ZK-D1090 User Manual
Copyright©2025 ZKTECO CO., LTD. All rights reserved.
Page | 35
Date of Maintenance Record of Maintenance Technician

Copyright@2025 ZKTECO CO., LTD. All rights reserved.
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 - 82109991
Fax : +86 755 - 89602394
www.zkteco.com