COMFIER CF-809A

Product's Documents

Below are documents related to this product, you can read online or download:

User manual

This is the main product document for model CF-809A.

The file format is pdf, 8 pages, you can download this manual here .

background
Full body vibration massager
User Manual
CF-809A
background
2
Safety Instruc�ons
IMPORTANT SAFEGUARDS
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE
PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER
– TO REDUCE THE RISK OF ELECTRIC SHOCK:
• Always unplug this appliance from the electrical outlet immediately a�er using and
before cleaning.
• DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
• DO NOT use while bathing or in a shower.
• DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
• DO NOT place in or drop into water or other liquid.
WARNING
– TO REDUCE THE RISK OF BURNS, ELECTRIC SHOCK, FIRE, OR INJURY
TO PERSONS:
• An appliance should NEVER be le� una�ended when plugged in. Unplug from
outlet when not in use, and before pu�ng on or taking off parts or a�achments.
• Close supervision is necessary when this appliance is used by, on, or near children,
invalids, or disabled persons.
• Use this appliance only for its intended use as described in this manual.
DO NOT use a�achments not recommended by COMFIER; specifically, any
a�achments not provided with the unit.
• NEVER operate this appliance if it has a damaged cord or plug, if it is not working
properly, if it has been dropped or damaged,or dropped into water. Return the
appliance to a COMFIER Service Center for examina�on and repair.
• Keep the cord away from heated surfaces.
• NEVER drop or insert any object into any opening.
• DO NOT operate where aerosol (spray) products are being used or where oxygen
is being administered.
• DO NOT operate under a blanket. Excessive hea�ng can occur and cause fire,
electric shock, or injury to persons.
• DO NOT carry this appliance by the supply cord or use cord as a handle.
• To disconnect, turn all controls to the off posi�on, then remove plug from outlet.
• NEVER operate the appliance with the air openings blocked. Keep the air openings
free of lint, hair, and the like.
• NEVER operate on a so� surface such as a bed or couch where the air openings may
be blocked.
• Keep long hair away from massager while in use.
• Recharge only with the charger provided with the unit. A charger that is suitable for
one type of ba�ery pack may create a risk of fire when used with another ba�ery pack.
• DO NOT use the massager with wet hands.
• DO NOT disassemble or drill into the product and/or ba�eries. This may cause
product malfunc�on, electric shock or fire
background
3
CAUTION:
In case of pregnancy or illness, consult your doctor before using massager.
SAVE THESE INSTRUCTIONS –
CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
• Consult your doctor prior to using this product, if:
- You are pregnant
- You have a pacemaker
- You have any concerns regarding your health
• Not recommended for use by people with diabetes.
• NEVER leave the appliance una�ended, especially if children are present.
• NEVER cover the appliance when it is in opera�on.
• DO NOT use this product for more than 15 minutes at a �me.
• Extensive use could lead to the product excessive hea�ng and shorter life.
Should this occur, discon�nue use and allow the unit to cool before opera�ng.
• NEVER use this product directly on swollen or inflamed areas or skin erup�ons.
• DO NOT use this product as a subs�tute for medical a�en�on.
• DO NOT use this product before bed. The massage has a s�mula�ng effect and can
delay sleep.
• NEVER use this product while in bed.
• This product should NEVER be used by any individual suffering from any physical
ailment that would limit the user’s capacity to operate the controls or who has
sensory deficiencies in the lower half of their body.
• This unit should not be used by children or invalids without adult supervision.
• NEVER use this product in automobiles.
• This appliance is intended for household use only
• Keep fingers, hair or any other body part away from the sha� and backside of the
applicator as pinching may occur.
• Use only on a dry surface of the body over clothing by lightly pressing and moving
across the body for approximately 60 seconds per region.
• Use the massager only on the body’s so� �ssue as desired,
• Stop use immediately if you feel pain or discomfort. Do not use on the head or any
hard or bony area of the body.
• Bruising can occur regardless of control se�ng or pressure applied. Check the
treated areas frequently and immediately stop at first sign of pain or discomfort.
• The muscle massager is intended for external applica�on to body parts only.
Opera�ng Instruc�ons Warning:
background
Changeable
massage head
Hand grip
Hand grip
Control Bu�ons
Flat Massage Head
PU Leather Head
Double Ball Head
Power adaptor
(Charger)
4
Features
TECHNICAL DATA
Measurements:
Weight:
Ba�ery:
Rated Power:
Ba�ery Full Charging:
Ba�ery Max. Run�me:
Default Automa�c Run�me:
15.7x8.7x7.3 INCHES
7.7 LBS
22.2V, 1800mAh.
26W
About 3 hours
280 minutes
15 minutes
Shockproof pad
Flat Massage head : for rela�on and shaping of various muscle parts.
Double Ball Head :For massaging the acupoints on the body.
PU Leather Head: For massagng arms, waist, back bu�ocks, thighs.
background
Opera�on instruc�ons
5
Power button:
Mode button:
As indicated above , the device will default to Mode 1.
Press this bu�on to choose the massage mode, can cycle through Mode 1/2/3,
the correspongding indicator lights up
Intensity(Speed level) button
Press the bu�on to adjust the massage intensity,can cycle through Low/Medium/High
speed,the correspongding indicator lights up
Mode 1 - Run con�nuously
Mode 2 - Short Pulse
Mode 3 - Long Pulse
A�achment / removal of accessory heads:
The heads are a compression fit into the muscle massager output socket. Simply align
the required head sha� with the socket and firmly press un�l the sha� is fully inserted.
To remove, simply pull the a�achment to withdraw from the socket.
WARNING: To avoid personal injury, never a�empt a�achment or removal when the
massager is in opera�on.
1. Turn off the massager before replacing another massage head.
2. Install the massage head as desired.
3. Turn on the massager by opera�ng the control bu�ons (instruc�ons as below)
4. To turn the massager off by pressing the power button. For your safety the device
will automa�cally turn off after 15 minutes of con�nuous use.
Instruc�on for use
Long press the Power bu�on for 3 seconds to turn on the machine, the default mode
is speed level(massage intensity)2 amd mode 1.
NOTE:
Do not setup or use the massager in a bathroom or similary wet / damp areas.
Do not use the massager while charging!
background
6
Ba�ery Charging and Life
Note: beforing using this product for the first �me, please fully charge it.
If the device is not in use for a long �me, the product should be charged
once a month to pretect the ba�ery life from shortening.
Ba�ery Disposal Warning:
The unit contains a Lithium Ion ba�ery.
Please contact your local recycling center to find out how to properly
dispose of the product.
Care and Maintenance
Care and cleaning instruc�ons
1. Always unplug the unit before cleaning it.
2. Before cleaning, allow unit to cool.
3. Dampen a cloth in water or a 3%–5% mild detergent solu�on.
4. Wipe the dirty areas with the wet cloth.
5. Do not use sharp brush, sharp tool, gasoline and diesel to clean it.
6. Do not use wet cloth clean control panel, lest cause failure, only use dry
cloth to wipe the control panel.
7. Never submerge any part of the unit in liquid.
8. Wait for the unit to become fully dry before use.
Maintenance
1. Please keep it in a safe, dry and cool place.
2. Do not keep it in any place with high temperature, near fire or direct
sunlight,or it may faded or damaged
3. Do not contact benzene, dilient or any other corrosive liquid.
Barrtery Charging
1. Connect the charging adapter cable to the corresponding port on the massager
2. Plug the charging adapter into an outlet.
3. Normally it takes about 3 hours to fully charge the ba�ery.
3. The power bu�on and speed indicator will flash when charging. When massager is
fully charged, the speed indicator stays on (blue).
4. Press and hold the power bu�on for 3 seconds to show the ba�ery capacity
(charge status),this can be done when the power is on or off.
5. If the ba�ery is full, the massager can work con�nuously for around 150-280 minutes.
6. Do not use the massager while charging!
NOTE:
A�en�on ! Please only use provided charging adapter.
Ba�ery Life
1.Ba�ery life varies depending on usage and may reduce over the life of the product.
2.If the product is not in use or a long �me, please keep in a charged state by
regularly charging.Ba�eries will last longer if kept recharged versus at a discharged
state.
3.Please keep the massager away from heat and avoid using in places
where the surrounding temperature is rela�vely hot.
4.During storage keep the power off and store the product in a cool place
background
7
Warranty
Troubleshoo�ng
Trouble Reason/Solu�on
Can not start the massager Ba�ery Low, Please charge it before using
The massager
stoped abnormally
Ba�ery runs out of power, charge the
ba�ery; Self-�med 15 mins is out, restart the
product
Massager slight noise
It is normal working noise of the internal
mechanism
30 days uncondi�onally return
Comfier product can be returned to receive a full refund for any reason within 30 days.
Please contact our customers service (supportus@comfier.com), our staff will contact
you within 24 hours.
90 days return/replace
Comfier product can be returned / replaced within 90 days if the product break
down in the period of proper use.
12 months Warranty
If the product breaks down within 12 months in the period of proper use,
customers can s�ll seek for the relevant product warranty to get it replaced.
A�en�on!
No warranty will be given to any force majeure or man-made causes for a defec�ve
product, such as improper care, personal tear down and willful damage, etc.
If you have any issue about the product, please feel free to contact us by sending
email to supportus@comfier.com We will strive to provide the best service
possible within 24 hours.
Extend Warranty for Free
1) Enter the following URL or scan the QR code below to find COMFIER facebook
page and like it, enter“Warranty” to messenger to extend your warranty from
1 year to 3 years.
h�ps://www.facebook.com/comfiermassager
OR 2) Send message“Warranty” and email us supportus@comfier.com to extend your
warranty from 1 year to 3 years.
Email: supportus@comfier.com
Tel: (248) 819-2623
Monday-Friday 9:00AM-4:30PM
background
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protec�on against harmful interference in a residen�al
installa�on. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruc�ons, may cause harmful
interference to radio communica�ons.However, there is no guarantee that
interference will not occur in a par�cular installa�on. If this equipment does cause
harmful interference to radio or television recep�on, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separa�on between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio / TV technician for help.
This device complies with Part 15 of the FCC Rules. Opera�on is subject to the following
two condi�ons: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
opera�on.
WARNING: Changes or modifica�ons to this unit is not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
FCC STATEMENT
COMFIER TECHNOLOGY CO.,LTD.
Address:573 BELLEVUE RD
NEWARK, DE 19713 USA
www.facebook.com/comermassager
supportus@comer.com
www.comer.com

Specifications

COMFIER CF-809A Questions and Answers