
Full Body Massage Mattress
User Manual
CF-3001

Safety Instructions
2
• The massage device conforms to recognized technical principles and the
latest safety regula�ons.
• Do not wet,do not use pins, never remove cover.
• This items is NOT A TOY. Close supervision is necessary when this
appliance is used by , on,or near children or disabled persons.
• This appliance should never be le� una�ended when plugged in.
• Any possible repairs may only be carried out by authorized expert staff.
Improper use and unauthorized repairs are not permi�ed for safety
reasons and lead to loss of warranty.
• Never touch the power plug with wet hands.
• Please avoid contact of the device with water, high temperatures and
direct sunlight.
• Do not use any damaged cables, plugs or loose sockets.
• If plugs or cords are damaged, they must be replaced by the manufacturer,
a service representa�ve or by qualified personnel.
• In case of malfunc�on, disconnect immediately from the mains.
• Do not use if you have skin disorders, open wounds,or swollen or inflamed
areas.
• Misuse or incorrect use excludes any liability for damage.
• Do not use while you sleep.
• In order to avoid excessively s�mula�ng the muscles and nerves, the
recommended massage �me should not be exceeded 15 minutes at
a �me.
• Each massage – even a hand massage – must be refrained from during
pregnancy or if one or more of the following complaints are present in
the massage area: recent injuries, thrombo�c diseases, all kinds of in
flamma�ons and swellings, and cancer. It is recommended to consult a
doctor before having a massage for the treatment of ailments and
illnesses.
• If you are dependent on electrical aids e.g. pacemakers, please be sure to
consult your doctor for medical advice before taking a massage.
• Do not use this product for medical treatment.

Item No. CF-3001
Thank you for purchasing Comfier Full Body Massage Ma�ress
Please be sure to read this User Manual carefully before use,
and save it for future reference.
• Full Body Massage Ma�ress
• Storage bag
• Home adapter
Contents
3
Technical Data
69 x 22 inches
16.5Lbs
Input: AC 100-240V ~50/60Hz
Output: 12VDC 3.5A
max. 42 Wa�
15 minutes
Measurements
Weight
Voltage
Nominal Power
Automatc runtme
:
:
:
:
:
:
Full Body Massage Mattress

4
1. Ma�ress with Shiatsu & 10 motors vibra�on massage for full body
2. Pillow (removable)
3. Extra pad (Removable, added to so�en the shiatsu massage intensity)
4. Home adapter
5. Power cord for main unit
6. Remote controller pouch
7. Remote controller
8. Carry handles
9. Hea�ng pad
Features
3
1
2
6
7
8
9
5
4

Setup and Operation
1. Place the massage ma�ress on the floor or on the bed.
2. Connect the adapter cable to the corresponding cable on the ma�ress.
3. Plug the home adapter into an outlet between 100-240V.
4. Turn on the device using the controller (Refer to below remote
controller instruc�on.)
5. When finished place the controller in the pouch at the side of
the ma�ress.
5
Demo buon:
Quick demonstraton of
the different func�ons.
The L.E.D.lights will blink
to indicate the ac�ve
func�ons. Once complete,
the device will
automatcally turn off.
Power buon:
turn the device ON
or OFF
Heat buon:
Turn ON/OFF the
heat func�on
Vibraon massage
regions buon:
Each massage regions may
be turned off or on as
desired by press the bu�on
for any combina�on of
regions and while any of
the 3 MODES are ac�ve.
Shiatsu buon:
Press to turn on or off
shiatsu func�on on back
Vibraon massage
intensity buon:
Press to change the
intensity ,You may cycle
through,Low,Medium,High
Shiatsu massage zone
buon:
you can choose upper,
lower or full back
Vibraon Mode buon:
Press to change the MODE
between M1 to M3.
Back spot buon:
Press to keep back shiatsu
in one area.
Use the ARROW bu�ons
to adjust the roller
posi�on up or down
Rolling buon:
press to ac�vate Rolling
func�on, the massage
heads travel up & down
across the muscle gently.
Con�nue pressing the
bu�on to adjust the width
of the massage heads to
custom fit the body.

Care and Cleaning Instructions
6
1. Do not wash in washing machine or immerse the product or the adapter
in water.
2. Always switch off before cleaning and remove the adapter from the
socket with clean, dry hands.
3. The massager should be wiped with a slightly moist cloth and dried
thoroughly. Do not wipe the product with alcohol or harsh chemicals
such as thinner or bleach.
4. Keep away from heat, fire or exposure to direct sunlight.
5. Store the massager in a cool, dry place out of reach of children.
6. Avoid contact with sharp edges or pointed objects which might cut or
puncture the fabric surface.
TROUBLESHOOTING GUIDE
Fault Solutions
The massage is not ac�ve in
all regions.
The massage motor for that region may have
been switched off. Press the bu�on that
corresponds to that region to ac�vate.
Device switches off suddenly
The device will switch off when the �mer runs
out.Con�nue using by pressing the ‘Power’
bu�on. If the device has run for 60 mins., turn
back on a�er res�ng the unit for 15 mins.
Over-heat protec�on func�on ac�vated.
Device is switched off for your safety . Please
rest device for 15-30mins before restar�ng.
Device fail to start
Check if device has been used for more than
30 mins.If so, let device rest for 15 mins before
con�nuing. Device may require longer �me to
cool in warmer environments.
Check if adapter is plugged into socket.
Check if adapter output is connected to device
power inlet wire.
Jerky mo�on of vibra�ons
from device
Excessive pressure may have been applied
onto the device. Reduce the load and try again.

Warranty
7
30 days uncondi�onally Return
Comfier product can be returned to receive a full refund for any reason within 30 days.
Please contact our customers service (supportus@comfier.com), our staff will contact
you within 24 hours.
90 days refund/replace
Comfier product can be returned / replaced within 90 days if the product break down
in the period of proper use.
12 months Warranty
If the product break down within 12 months in the period of proper use, customers can
enjoy the relevant warranty to get them replaced.
A�en�on!
No warranty will be given to any force majeure and man-made causes to a defec�ve
product, such as improper care, personal tear down and willful damage,etc.
If you have any issue about the product, please feel free to contact us by sending
email to supportus@comfier.com We will strive to provide the best service
possible within 24 hours.
Tel: (248) 819-2623
Monday-Friday 9:00AM-4:30PM
Email: supportus@comfier.com
Extend Warranty for Free
1) Enter the following URL or scan the QR code below to find COMFIER facebook
page and like it, enter“Warranty” to messenger to extend your warranty from
1 year to 3 years.
h�ps://www.facebook.com/comfiermassager
OR 2) Send message“Warranty” and email us supportus@comfier.com to extend your
warranty from 1 year to 3 years.
Have queson ?

NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protec�on against harmful interference in a residen�al
installa�on. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruc�ons, may cause harmful
interference to radio communica�ons.However, there is no guarantee that
interference will not occur in a par�cular installa�on. If this equipment does cause
harmful interference to radio or television recep�on, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separa�on between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio / TV technician for help.
This device complies with Part 15 of the FCC Rules. Opera�on is subject to the following
two condi�ons: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
opera�on.
WARNING: Changes or modifica�ons to this unit is not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
FCC STATEMENT
