Dirt Devil SD65000 5 Gallon Wet/Dry Vacuum

Product's Documents

Below are documents related to this product, you can read online or download:
SD65000 photo

Product manual

This is the main product document for model SD65000.

The file format is pdf, 6 pages, you can download this manual here .

background
Do not use Wet/Dry Vacuum as a sprayer.
Do not direct air at bystanders.
Keep children away when blowing.
Wear safety goggles.
DOUBLE INSULATION INSTRUCTIONS
This Wet/Dry Vacuum is double insulated,
eliminating the need for a separate grounding
system. Use only identical replacement parts.
Read the instructions for Servicing Double-
Insulated Wet/Dry Vacuums before servicing. Use
this vacuum as described in this manual. Observe
the following warnings that appear on the motor
housing of your vacuum.
DOUBLE INSULATED–Grounding not
required–When servicing use only identical
replacement parts.
WARNING: To reduce the risk of
electric shock–Do not expose to rain. Store
indoors.
WARNING: For your own safety,
read and understand the operator’s manual.
Do not run unattended. Do not pick up hot
ashes, coals, toxic, flammable, or other
hazardous materials. Do not use around
explosive liquids or vapors.
CAUTION: Do not vacuum drywall
dust, fireplace soot, or ash with standard wet/
dry filter. This type of dust is very fine which
may not be captured by the filter and cause
damage to motor.
WARNING: Servicing of double-
insulated wet/dry vacuum–With a double-
insulated wet/dry vacuum, two systems of
insulation are provided instead of grounding.
No grounding means is provided on a double-
insulated appliance, nor should a means
for grounding be added. Servicing a double
insulated wet/dry vacuum requires extreme
care and knowledge of the system and should
be done only by qualified service personnel.
Replacement parts for a double-insulated
wet/dry vacuum must be identical to the parts
they replace. Your double-insulated wet/
dry vac is marked with the words ‘DOUBLE
INSULATED’ and the symbol
(square
within a square) may also be marked on the
appliance.
5 GALLON
WET/DRY VACUUM
USER MANUAL
IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY AND USE.
This product is intended for Household use only. If used Commercially warranty is VOID.
©2024 Techtronic Floor Care Technology Limited. Distributed by, Royal Appliance Mfg. Co. Charlotte, NC 28262. 961152311-R0
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
READ ALL SAFETY WARNINGS AND INSTRUCTIONS BEFORE USING THIS PRODUCT.
WARNING: To reduce the risk of fire,
electric shock, or injury:
Do not run vacuum unattended.
Do not use to pick up flammable or combustible
liquids, such as gasoline, or use in areas where
they may be present.
Do not vacuum, or use this vacuum near
flammable liquids, gases, or explosive vapors
like gasoline or other fuels, lighter fluids,
cleaners, oil-based paints, natural gas,
hydrogen, or explosive dusts like coal dust,
magnesium dust, grain dust, or gun powder.
Sparks inside the motor can ignite flammable
vapors or dust.
To reduce the risk of health hazards from vapors
or dusts, do not vacuum toxic materials.
Do not use or store near hazardous materials.
Do not pick up anything that is burning or smoking,
such as cigarettes, matches, or hot ashes.
Do not expose to rain. Store indoors.
If vacuum is not working as it should, has been
dropped, damaged, left outdoors, or dropped
into water, return it to a service center.
Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
Do not use with damaged cord or plug.
Do not pull or carry by cord, use cord as a
handle, close a door on cord, or pull cord around
sharp edges or corners.
Keep cord away from heated surfaces.
Do not run the vacuum over cord.
Do not handle plug or vacuum with wet hands.
Do not use without dust bag and/or filters in
place.
Do not allow to be used as a toy. Close attention
is necessary when used by or near children.
To reduce the risk of injury from accidental
starting, unplug power cord before changing or
cleaning filter.
Do not leave vacuum when plugged in. Unplug
from outlet when not in use and before
servicing.
Turn o all controls before unplugging.
Unplug before connecting or disconnecting
hose, or any other accessories.
Do not put any object into openings. Do not use
with any opening blocked; keep free of dust,
lint, hair, and anything that may reduce air flow.
Keep hair, loose clothing, fingers, and all parts
of body away from openings and moving parts.
Use extra care when cleaning on stairs.
Use only as described in this manual. Use only
manufacturer’s recommended attachments.
This vacuum is provided with double insulation.
Use only identical replacement parts.
DOUBLE INSULATION INSTRUCTIONS.
Local regulations or bylaws may determine the
minimum age for using the device.
Children must be supervised in order to ensure
that they do not play with the equipment.
Do not lift or transport the tool while the motor
is running. Turn the tool o and wait for the
tines to stop moving, then disconnect the tool
from the mains before changing the area you
are working on.
If the connecting cable to this equipment
is damaged, it must be replaced by the
manufacturer, the customer service of the
same, or a similarly qualified person in order to
avoid hazards.
CAUTION: To reduce the risk of injury
from moving parts–Unplug before servicing.
WARNING: To reduce the risk of electric
shock–Unplug before cleaning or servicing.
WHEN USING AS BLOWER:
Direct air discharge only at work area.
Contact Dirt Devil
®
Support for
assistance with your pressure washer
.
DO NOT
RETURN TO STORE
Chat with us!
dirtdevil.com/pages/ddcontact
Every day 8am-8pm EST
background
GENERAL ASSEMBLY
INSTRUCTIONS
A Philips head screw driver is required.
WARNING: DO NOT PLUG THE POWER
CORD INTO A POWER OUTLET. MAKE SURE THE
PLUG IS DISCONNECTED BEFORE ASSEMBLING
THE WET/DRY VACUUM. TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN.
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
7
8
9
10
6
5
1
2
2.
Undo the latches.
7
8
9
10
6
5
1
2
3.
Lift the power head o the collection tank.
7
8
9
10
6
5
1
2
4.
Remove the contents from inside the collection
tank. Make sure you have all contents.
7
8
9
10
6
5
1
2
5.
Turn the collection tank upside down and insert
the four casters into the slots on the bottom
of the collection tank. Ensure each caster is
aligned straight into the collection tank and apply
pressure until the casters snap into place.
6
6.
Insert the handle into the slots located on the top
of the power head and secure it with the screws
provided. Do not over-tighten the screws.
7.
Your vacuum comes ready for dry vacuum
cleaning. If the reusable cloth filter is not
installed.
7
8
9
10
6
5
1
2
8.
For wet vacuum cleaning, remove the reusable
cloth filter, and install the supplied foam wet
filter. Refer to the foam wet filter installation
instructions.
7
8
9
10
6
5
1
2
9.
Place the power head back on the collection tank,
aligning the top section with the latches, and
snap into place.
SYMBOLS
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
Indicates a hazardous situation, which, if not avoided, will result in death or serious
injury.
WARNING:
Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.
CAUTION:
Indicates a hazardous situation, that, if not avoided, may result in minor or
moderate injury.
NOTICE:
(Without Safety Alert Symbol) Indicates information considered important, but not
related to a potential injury (e.g. messages relating to property damage).
EXTENSION CORDS
When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the
required A.W.G. wire size. Before using the vacuum make sure the power cord and extension cord are
in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use
extension cords that are rated for outdoor use.
Length of Extension Cord
120V 25ft (7.62m) 50ft (15.24m) 100ft (30.48m) 150ft (45.72m)
Ampere rating
A.W.G. Wire Size
More than Not more than
0 6 18 16 16 14
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not recommended
UNPACKING & CHECKING
CARTON CONTENTS
Fully assemble product prior to use.
Remove all contents from the box. Remove the
power head and take out any contents inside
the collection tank. Check each item against the
carton contents list.
CARTON CONTENTS LIST:
Key Description ......................................... Qty
A Vacuum Assembly..........................................1
B Handle ............................................................. 1
C Hose .................................................................4
D 2-in-1 Utility Nozzle ...................................... 1
E Caster ..............................................................2
F Extension Wand ..............................................1
G Floor Brush/Squeegee Nozzle ...................... 1
H Noise Diuser .................................................1
I Reusable Cloth Filter ..................................... 1
J Foam Wet Filter .............................................. 1
K 2 Screws (Bag) ...............................................1
L Operator’s Manual ..........................................1
NOTE: The hose and accessories for this vacuum
are 1-1/4’’ (3.2 cm) diameter.
C
B
E
D
G
K
H
I
J
F
A
L
Blower Port
Accessory
Storage
Latch
Caster
Power Head
Handle
On-Off Switch
Vacuum Port
Collection Tank
background
7
8
9
10
6
5
1
2
10.
Insert the locking end of the hose into the
vacuum port on the collection tank and turn
clockwise to lock into place.
7
8
9
10
6
5
1
2
11.
Choose the desired attachment and insert onto
the end of the hose or extension wand.
NOISE DIFFUSER
For quiet operation, install the noise diuser
into the blower port by inserting the locking end
of the diuser into the blower port and turning
clockwise to lock into place.
POLARIZED PLUG
To reduce the risk of electrical shock, this
appliance has a polarized plug (one blade wider
than the other). This plug will fit in a polarized
outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician to install the
proper outlet. Do not change the plug in any way.
Double insulation eliminates the need for the
three-wire grounded power cord and grounded
power supply system.
DRY VACUUM OPERATION
DRY VACUUMING
WARNING: BE SURE TO READ,
UNDERSTAND, AND APPLY INFORMATION
ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”.
DO NOT VACUUM IN AREAS WITH FLAMMABLE
GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE
AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT
ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE,
ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE
DUSTS INCLUDE BUT ARE NOT LIMITED TO:
COAL, MAGNESIUM, GRAIN, OR GUN POWDER.
TO REDUCE THE RISK OF HEALTH HAZARDS
FROM VAPORS OR DUST, DO NOT VACUUM TOXIC
MATERIALS.
WARNING: DO NOT PLUG THE POWER
CORD INTO A POWER OUTLET. MAKE SURE THE
PLUG IS DISCONNECTED BEFORE CHANGING THE
FILTERS.
CAUTION: DO NOT VACUUM DRYWALL
DUST, OR FIREPLACE SOOT, OR ASH WITH
STANDARD WET/DRY FILTER. THIS IS A VERY
FINE DUST WHICH WILL NOT BE CAPTURED BY
THE FILTER AND MAY CAUSE DAMAGE TO MOTOR.
WHEN VACUUMING FINE DUST USE A FINE DUST
FILTER (SOLD SEPARATELY).
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
7
8
9
10
6
5
1
2
2.
In order to prepare your vacuum for dry
vacuuming, make sure the reusable cloth filter
completely covers the filter cage. Your wet/dry
vacuum comes with the reusable cloth filter
pre-installed. For installation instructions, see
INSTALLING & CLEANING REUSABLE CLOTH FILTER.
3.
Place the power head back on the collection tank
and secure it in place using the latches.
OPERATING INSTRUCTIONS: DRY
VACUUMING
4.
Insert the locking end of the hose into the
vacuum port on the collection tank and lock into
place.
7
8
9
10
6
5
1
2
5.
Push the required attachment onto the free end of
the hose or extension wand.
6.
Verify that the switch is in the ‘O’ OFF position
before plugging the power cord into the power
outlet.
7
Plug the power cord into the outlet.
8.
Turn the motor on by flipping the on/o switch to
the ‘I’ ON position and begin vacuuming.
7
8
9
10
6
5
1
2
9.
Once you have completed vacuuming, flip the on/
o switch to the ‘O’ OFF position and unplug the
power cord from the outlet.
O = OFF I = ON
DO NOT USE THE REUSABLE CLOTH FILTER FOR
LIQUID VACUUMING.
LIQUID VACUUM
OPERATION
WARNING: BE SURE TO READ,
UNDERSTAND, AND APPLY INFORMATION
ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”.
DO NOT VACUUM IN AREAS WITH FLAMMABLE
GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE
AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT
ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE,
ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE
DUSTS INCLUDE BUT ARE NOT LIMITED TO:
COAL, MAGNESIUM, GRAIN, OR GUN POWDER.
TO REDUCE THE RISK OF HEALTH HAZARDS
FROM VAPORS OR DUST, DO NOT VACUUM TOXIC
MATERIALS.
WARNING: DO NOT PLUG THE POWER
CORD INTO A POWER OUTLET. MAKE SURE THE
PLUG IS DISCONNECTED BEFORE CHANGING THE
FILTERS.
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet. Make sure that the collection tank is
clean and free of dust and dirt.
7
8
9
10
6
5
1
2
2.
Remove the reusable cloth filter, then carefully
install the foam wet filter over the filter cage and
place the power head back on the collection tank.
For foam wet filter installation instructions, see
INSTALLING & CLEANING FOAM WET FILTER.
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID
VACUUMING.
OPERATING INSTRUCTIONS: WET
VACUUMING
3.
Insert the locking end of the hose into the
vacuum port on the collection tank and lock into
place.
background
7
8
9
10
6
5
1
2
4.
Push the required attachment onto the free end of
the hose or extension wand.
7
8
9
10
6
5
1
2
5.
Verify that the on/o switch is in the ‘O’ OFF
position before plugging the power cord into the
power outlet. Plug the power cord into the outlet.
6.
Turn the motor on by flipping the switch to the ‘I
ON position.
7.
Once you have completed vacuuming, flip the on/
o switch to the ‘O’ OFF position and unplug the
power cord from the outlet.
8.
After use, empty the collection tank, clean and
dry the inside and outside the collection tank.
IMPORTANT: When vacuuming large quantities
of liquids, do not immerse the nozzle completely
in the liquid; leave a gap at the tip of the nozzle
opening to allow air inflow. The machine is fitted
with a float valve that stops the suction action
when the collection tank reaches its maximum
capacity. You will notice an increase in motor
speed. When this happens, turn o the machine,
disconnect from power supply, and empty the
liquid into a suitable receptacle or drain. To
continue vacuuming, refit the power head to the
collection tank. After wet vacuuming, turn the
machine o and remove plug from power supply.
Empty the collection tank, clean, and dry the
inside and outside before storage.
REMEMBER: The foam wet filter must be
removed after wet vacuuming and the reusable
cloth filter must be installed before dry
vacuuming again.
BLOWER OPERATION
This Wet/Dry Vacuum has blowing capabilities.
To use the blower feature, follow the instructions
listed.
WARNING: ALWAYS WEAR SAFETY
GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN
CANADA, CSAZ94.3) BEFORE USING BLOWER.
CAUTION: KEEP BYSTANDERS CLEAR
FROM BLOWING DEBRIS.
WARNING: WEAR A DUST MASK
IF BLOWING CREATES DUST THAT MIGHT BE
INHALED.
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
2.
Make sure the collection tank is empty before
using as a blower. Clear all dirt and debris from
the hose and collection tank.
2
3.
Remove the hose from the vacuum port. Remove
noise diuser from blower port.
4.
Secure the larger end of the hose into the blower
port on the back of the power head and lock into
position.
5.
Fit the desired attachment onto the hose.
6.
Verify that the on/o switch is in the ‘O’ OFF
position before plugging the power cord into the
outlet. Plug the power cord into the outlet.
7.
Before turning on the vacuum, firmly hold loose
end of the hose. Turn the motor on by flipping the
switch to the ‘I’ ON position.
7
8
9
10
6
5
1
2
8.
Once you have completed blowing, flip the on/
o switch to the ‘O’ OFF position and unplug the
power cord from the outlet.
MAINTENANCE
EMPTYING THE COLLECTION TANK
WARNING: ALWAYS DISCONNECT
THE PLUG FROM THE POWER OUTLET BEFORE
REMOVING THE POWER HEAD FROM THE
COLLECTION TANK.
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
2.
Disconnect the hose from the vacuum.
7
8
9
10
6
5
1
2
3.
Undo the latches and remove the power head
from the collection tank. Place power head on a
soft, clean surface upside down.
4.
Clear all dirt or debris from the collection tank
and hose into a proper waste container.
5.
Clean or replace the filters.
6.
Check the hose, attachments, and power cord to
ensure that they have not been damaged.
7.
Place the power head back on the collection tank
and secure latches.
background
IMPORTANT: Clean or change the filter regularly
for best performance. ALWAYS USE THE
REUSABLE CLOTH FILTER FOR DRY VACUUMING”.
If the machine is used without the reusable cloth
filter, the motor will burn out and the warranty
will be voided. Always keep spare filters on hand.
NOTICE: The filters included are made of high-
quality materials designed to stop small dust
particles. The reusable cloth filter should be
used for dry pick-up only. A dry reusable cloth
filter is necessary to pick up dust. If the reusable
cloth filter is wet, it will clog quickly and be very
dicult to clean. Handle the filter carefully when
removing it for cleaning or replacing. Check the
filters for tears or small holes. A small hole can
let dust pass through and out of the filter. Do
not use a filter with holes or tears; replace it
immediately.
STORAGE
Before storing your vacuum, the collection tank
should be emptied and cleaned. The accessories
should be cleaned and stored so they can be
readily available when needed. Store the wet/dry
vacuum indoors.
REPAIRS
Repairs for this wet/dry vacuum should be
performed only by qualified service personnel
using only identical replacement parts.
INSTALLING & CLEANING
REUSABLE CLOTH FILTER
INSTALLATION AND CLEANING OF THE
REUSABLE CLOTH FILTER
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
2.
Remove the power head and place in an upside-
down position.
7
8
9
10
6
5
1
2
3.
Install the reusable cloth filter over the filter cage
making sure the cage is completely covered.
4.
Place the power head back onto the collection
tank.
REMOVING & CLEANING REUSABLE
CLOTH FILTER
1.
With the removed power head in an upside-down
position, carefully remove the reusable cloth filter
from the filter cage.
2.
Clean the reusable cloth filter by gently tapping
or brushing dirt o. Cleaning should not be done
indoors in living areas. For optimal performance,
a new filter is recommended.
3.
Use a mild soap and water solution to wash
reusable cloth filter and rinse with clean water.
4.
Allow the wet filter to air dry for 24 hours before
installing onto the filter cage.
INSTALLING & CLEANING
FOAM WET FILTER
INSTALLING FOAM WET FILTER
7
8
9
10
6
5
1
2
1.
Verify that the power cord is disconnected from
the outlet.
2.
Remove the power head and place in an upside-
down position. Follow instructions to remove the
reusable cloth filter at INSTALLING & CLEANING
REUSABLE CLOTH FILTER.
7
8
9
10
6
5
1
2
3
3.
Carefully slide the foam wet filter down over the
filter cage making sure the cage is completely
covered.
4.
Place the power head onto the collection tank.
CLEANING FOAM WET FILTER
4
1.
With the removed power head in an upside-down
position, carefully remove the foam wet filter.
2.
Use a mild soap and water solution to wash the
foam wet filter and rinse with clean water.
3.
Allow the wet filter to air dry for 24 hours before
installing onto the filter cage.
background
WARRANTY
LIMITED WARRANTY FOR DIRT DEVIL
®
PRODUCT / 2 (TWO) YEARS LIMITED WARRANTY (DOMESTIC USE)
If this product is not as warranted, contact TTI
Floor Care North America Customer Service at
1-800-944-9200. Please have available the
proof of purchase and model number for the
warranted product.
Failure to register the product does not diminish
product warranty rights.
WHAT THIS WARRANTY COVERS: This limited
warranty provided by Royal Appliance Mfg.
Co., doing business as TTI Floor Care North
America (referred to hereafter as “Warrantor”)
applies only to products purchased in the U.S.
(including its territories and possessions), a
U.S. Military Exchange, or Canada. When used
and maintained in normal household use and in
accordance with the Owner’s Guide, this product
is warranted against original defects in material
and workmanship for 2 (Two) years from the
date of original purchase (the “Warranty Period”).
If Warrantor determines that the issue you are
experiencing is covered under the terms of this
warranty (a “covered warranty claim”), we will,
at our sole discretion and free of charge (subject
to the cost of shipping), either (i) repair your
product; (ii) ship you a replacement product,
subject to availability; or (iii) in the event that
the applicable parts or replacement are not
reasonably available, ship you a similar product
of equal or greater value. In the unlikely event
that we are unable to repair your product or ship
a replacement or similar product, we reserve
the right, at our sole discretion, to issue you
a refund or store credit (if applicable) of the
actual purchase price at the time of the original
purchase as reflected on the original sales
receipt. Parts and replacements may be new,
refurbished, lightly used, or remanufactured, in
Warrantor’s sole discretion.
WHO THIS LIMITED WARRANTY COVERS: This
limited warranty extends only to the original
retail purchaser, with original proof of purchase
from Warrantor or an authorized dealer of
Warrantor products, in the U.S., U.S. Military
Exchanges, and Canada.
WHAT THIS WARRANTY DOES NOT COVER: This
warranty does not cover use of the product
in a commercial operation (such as maid,
janitorial, and equipment rental services, or any
other income-generating activity); improper
maintenance of the product; the product if it has
been subject to misuse, negligence, neglect,
vandalism, or the use of voltages other than that
on the data plate of this product. This warranty
does not cover damage resulting from an act
of God, accident, owner’s acts or omissions,
service of this product by other than Warrantor
or a Warrantor authorized service provider (if
applicable), or other acts beyond the control of
Warrantor. This warranty also does not cover use
outside the country in which the product was
initially purchased, or resale of the product by the
original owner. Pick-up, delivery, transportation,
and house calls are not covered by this warranty.
In addition, this warranty does not cover any
product that has been altered or modified, or
repairs made necessary by normal wear or the
use of other products, parts, or accessories
which are either incompatible with this product
or adversely aect this product’s operation,
performance, or durability. Normal wear items
are not covered under this warranty. Depending
on the product, normal wear items may include,
but are not limited to, belts, filters, brush rolls,
blower fans, blower and vacuum tubes, and
vacuum bags and straps.
OTHER IMPORTANT TERMS: This warranty
is not transferable and may not be assigned;
any assignment made in contravention of
this prohibition is void. This warranty shall be
governed and construed under the laws of the
state of North Carolina. The Warranty Period will
not be extended by any replacement of batteries,
parts, or products or by virtue of any repair
performed under this warranty.
THIS LIMITED WARRANTY IS THE EXCLUSIVE
WARRANTY AND REMEDY, AND ALL EXPRESS AND
IMPLIED WARRANTIES OTHER THAN THE LIMITED
WARRANTY SET FORTH ABOVE, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE EXPRESSLY
DISCLAIMED. IN NO EVENT WILL WARRANTOR BE
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY KIND OR
NATURE TO OWNER OR ANY PARTY CLAIMING
THROUGH OWNER, WHETHER BASED IN CONTRACT,
NEGLIGENCE, TORT, OR STRICT PRODUCTS LIABILITY
OR ARISING FROM ANY CAUSE WHATSOEVER,
EVEN IF THIS WARRANTY FAILS OF ITS ESSENTIAL
PURPOSE. TO THE EXTENT PERMITTED BY
APPLICABLE LAW, NO WARRANTIES THAT ARISE
BY OPERATION OF LAW, IF APPLICABLE, SHALL
EXCEED THE DURATION OF THE LIMITED WARRANTY
PROVIDED HEREIN. Warrantor’s liability for
damages to you for any costs whatsoever arising
out of this statement of limited warranty shall be
limited to the amount paid for this product at the
time of original purchase.
Some states do not allow the exclusion or
limitation of incidental or consequential
damages, disclaimers of implied warranties, or
limitations on the duration of implied warranties,
so the above exclusions, disclaimers, and/or
limitations may not apply to you. This warranty
gives you specific legal rights, and you may also
have other rights, which vary from state to state.
GENUINE PARTS AND ACCESSORIES: We
recommend using only with genuine Dirt Devil®
parts, and accessories. Damage caused by use
with other than genuine Dirt Devil® parts, and
accessories is not covered by and may void your
warranty.
TROUBLESHOOTING
WARNING: To reduce the risk of electric shock, unplug before troubleshooting.
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The wet/dry vacuum will not operate.
1. No power supply. 1. Check the power supply, cord, breakers, and fuses.
2. Faulty power cord. 2. Unplug and check the power cord. If damaged, have it repaired by a professional.
3. Collection tank is full. 3. Empty the collection tank.
4. Switch in the wrong position. 4. Press the ON ‘I’ button on the power head.
The dust comes out from the motor cover.
1. The reusable cloth filter is missing or damaged. 1. Attach or replace the reusable cloth filter.
2. Vacuum has been used to collect fine dust, such as dry wall dust, fireplace soot, or
ash, without a fine dust filter.
2. Remove the reusable cloth filter and install the appropriate fine dust filter.
Reduced eciency and motor/speed vibration.
1. There are blockages in the nozzle, hose, or the collection tank inlets. 1. Unplug and check nozzle, hose and collection tank inlets for blockages.
2. The reusable cloth filter is clogged by fine dust. 2. Take o the filter and clean it or install a new reusable cloth filter.
SERVICE PARTS
PART PART NUMBER
Standard Cartridge Filter AD41000
Wet Foam Filter AD43000
Dust Collection Bags (2PK) AD11000

Specifications

Indexed Terms: Wet & Dry Vacuum

Dirt Devil SD65000 Questions and Answers