![](https://files.manualsfile.com/54327019-hm-td5567t-7-w/bg24.png)
16.7-1000
(focus
distance)
12.5-775
(focus
distance)
15.6-500
(focus
distance)
6.7-330
(focus
distance)
10-320
(focus
distance)
6-240
(focus
distance)
The left column is optical ratio, the right columns are speed level.
15
km
15 4 20 4 / / / / / / / /
10
km
10 5 15 4 12 4 / / / / / /
5 km 7 6 10 5 8 5 20 4 13 4 / /
3 to
5 km
5 6 7 6 6 6 13 4 9 5 15 4
4.5 Set Fire Detection Parameters
To avoid the potential re damage, you should congure the re detection function for
certain areas. The detail conguration steps show as below.
Before You Start
●
The re detection function can locate the re source area quickly together with patrol or
linear scan. Please refer to
Set Patrol Scan
for conguring patrol. Please refer to
Set the
Presets
for presets setting.
●
Please refer to
Set Device Position
for locating the re source position.
●
Go to Conguration > Local , set the re point parameters.
Locate Highest Temperature Point
Click and save to show the position of the highest temperature on the interface.
Frame Fire Point
Click and save to frame the detected re source.
Steps
1.
Go to Conguration > Event > Smart Event , select Fire and Smoke Detection.
2.
Check Enable Fire and Smoke Detection.
3.
Refer to
Detection Mode and Application Scene
for setting the re detection mode.
4.
Check Display Fire Source Frame on Stream to display a red frame around the re source
on stream when re occurs.
5.
Setting the parameters of re detection.
Detection Mode
by Single Frame
It can quickly detect re while moving, but have a high false positive rate.