AXIS Q6035 PTZ Dome Network Camera
Events
Events
Predefined parameters, known as an Event or Event Type, can trigger actions in the Axis product. A common event type is an alarm
that causes the product to upload images to an Ev en t S erver.
Triggered events - are activated by a signal, for example motion detection.
Scheduled events - run at p reset times, in a repeating pattern on selected weekdays.
Actions - refer to what happens when an event occurs.
Triggered events can be activated by:
• Input ports
• Motion detection, see
page 33
• Audio detection, see
page 35
• A trigger from an uploaded application, see
Applications, on page 29
• Pan Tilt Zoom — when the view stops at a preset p osition
• Full disk — when the SD card has less than 1 MB free m emory left
• System events, for example on boot.
Event actions include:
• Uploading images to an event server or send images by email
• Savingthevideostreamtotheproduct’sSDcard
• Sending notification mess ages and emails
• Activating an output port, for example, to sound an alarm or lock a door
• Pan Tilt Z oom — go to a preset
Event Servers
Event servers re
ceive uploaded image files and/or notification messages. To set up event server connections in the Axis p roduct, go
to Events > Event Servers and enter the required information for the server type.
Note
Email server s are configured under System Options > Network > SMTP (email) .
When the setup is complete, click Test to test the connection (the c onnection test takes approximately 10 seconds).
Server type
Purpose
Information required
FTP Server
• Receives uploaded images • Descriptive name
• Network address and upload path
• User n ame and password