2.3.2 Installing the Camera
2.3.2.1 WALL SURFACE MOUNT
Install the environmental IR bullet camera to a wall surface as shown in the following procedure.
NOTE: The mounting height above ground level shall be more than 3 meters for wall mount height.
FIGURE 2-1: MOUNTING TEMPLATE FOR WALL SURFACE MOUNT FIGURE 2-3: WALL SURFACE MOUNT 2/2
FIGURE 2-2: WALL SURFACE MOUNT 1/2
1. Drill 6 mm (0.25”) outer holes based on the mounting template and hammer the plastic anchors into the holes.
2. Pass all the cable through the mounting hole (I) or pass the cable through the side cutout of the bracket (II) according to
your application. As an installation best practice, ensure the cutout if facing down. Refer to 2.3.3 Connecting the Cables
to connect the required cables.
NOTE: When installing your Bullet Series camera using method (II), it is recommended that the connections be made in a
junction box to protect against environmental factors such as dust and water.
3. Tighten the camera onto the surface by fastening the included tapping screws securely.