COMPACT RECHARGEABLE TYRE INFLATOR
& POWERBANK WITH WORK LIGHT
MODEL NO: CTI120
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Read operation instructions before use.
8 DO NOT leave the unit unattended while in operation.
9 Checkcapacityandmaximuminationpressureofinatablebeforecommencingination.
9 Monitorthepressuregaugewhileinoperation.
9 Thegaugeshouldbeusedasanindicationofpressureonly.Werecommendtheuseofadialpressuregaugefordenitivereading.
WARNING!Thiscompressoriscapableofproducingahighpressure.
8 DO NOTinateanyitembeyonditsmaximumcapacity.
8 DO NOTdirectinationhoseconnectorheadatyourself,othersoranimals.
8 DO NOTcarrybythehose,oryankthehosefromaninationvalve.
8 DO NOT pull the power cable from the vehicle accessory socket by the power lead.
8 DO NOTgetthecompressorwetoruseintherain.
8 DO NOTusethecompressorforataskitwasnotdesignedtoperform.
8 DO NOToperatethecompressorifanypartsaremissingasthismaycausefailureorpossiblepersonalinjury.
8 DO NOT open the unit.
9 Keepchildrenandnonessentialpersonsawayfromtheinationarea.
9 Keepthecompressorcleanandingoodcondition.
9 Avoidbendingthehoseduringination.
9 Turnothepumpimmediatelyifoverheatingoranyabnormalityisobservedduringoperation.
9 Ifnopresetpressurevalue,DO NOTleavethepumpunattendedduringinationtopreventtheairpressuregettingtoohigh.
9 Keepthepumpawayfromanyammableorcombustibleobjectsduringoperation,sincethebuilt-inDCmotormaygeneratesparks
duringoperation.
9 Keepthepumpawayfrommoisture,sandandshock.
8 DO NOTstorethepumpinextremelycoldorhotplaces.Thatwillshortenproductlife,damagebattery,ordeformthestructural.
9 Avoidusingstrongchemicalsordetergentstocleantheproduct.
8 DO NOT disassemble the product. DO NOTthrowtheproductintoreorhouseholdwaste.
8 DO NOT let children use the product.
8 DO NOTinsertthehoseintomouth,ears,oreyesofhumansoranimals.Itmustnotbeusedasatoy.
9 Thiscompressorisnotdesignedforcontinuoususe.Operationoveranextendedperiodoftimewilloverheattheunitanddamage
thecompressor.Itshouldnotbeusedcontinuouslyformorethan30minutes.After30minutes,turnitoandletitcoolfor15
minutesbeforeresumingoperation.
CTI120Issue3(2)04/08/20
Original Language Version
© Jack Sealey Limited
Refer to
instructions

2. INTRODUCTION
Compactdigitaltyreinatorwithoutputof12L/min.Pressuregaugereadsupto120psi(kPa,kg/cm²andbarequivalents).140mmExtension
tubewithSchraderconnection.MicroUSBrechargeable(cablesupplied).USBoutputforchargingmobilephoneetc.(5V/2A).Suppliedwith
sportsballpinadaptor,balloon/inatablesadaptorandalsoaPrestavalveadaptorforroadbicycletyres.Built-in1WSMDLEDforeaseof
useatnight.Presetthedesiredpsitobeginoperationandunitwillcut-outautomaticallyoncethatpressureisreached.Autocut-outifhose
kinks,toavoiddamagetopump.
1.OutletGrid 2.Pressuregauge 3. Reduce button 4.IncreaseButton
5.UnitButton 6.Start/Stopbutton 7.LEDLightingbutton 8.Indicator
9.Inletgrid 10.LEDLighting 11.HoseConnector 12.OutletGrid
13.USBoutputport 14.MicroUSBinputport 15.Airhose 16.4×Valveadapters
3. SPECIFICATION
HoseLength:.............................................................. 140mm
TypicalInationTime: .......... 0-30psiin619sec(175/70/R13)
MaximumPressure: .................................................... 120psi
Airow: ........................................................0.42cfm/12ltr/min
USB Output: ................................................................. 5V/2A
Battery: ......................................................2000mAh/22.2Wh
4. OPERATION
4.1. CHARGING
4.1.1. Pleasechargethebatteryfullybeforeuse(g.2).Especially
forthersttimeorafteritisunusedforalongtime.Charge
forabout4hoursforfullcharge.Otherfunctionsoftheproduct
arenotavailableduringcharging.
4.2. USING THE USB CHARGING PORT
4.2.1. USB output of CTI120isplugandplay.
4.2.2. Theairpumpwillnotwork,whenyouare
chargingadevicefromthetyreinator.
TheUSBoutputwillturnoautomatically.
g.3
Original Language Version
© Jack Sealey Limited
CTI120Issue3(2)04/08/20
g.2
g.1
Micro USB cable
not shown

4.3. USING THE LED LIGHT
4.3.1. PresstheLEDlightbuttononce(g.4)toturnonthelight.Pressthebuttontwiceforaslowash,andthreetimesforaSOS
ashinglightpattern.
4.4. SETTING THE PRESSURE
NOTE:
• Whenthepre-setvalueislowerthanthevalueofperipheralpressure,theairpumpcannotbeactivated.
• CTI120hasanintegratedmechanismfortemperatureprotection.Self-protectionwillbeactivatedtostopexternalinationwhenthe
temperatureexceeds-15°Cto55°C.Itshouldnotbeusedcontinuouslyformorethan30minutes.After30minutes,turnitoandletit
coolfor15minutesbeforeresumingoperation.
• Arecommendedinationrangeislabelledonthesideoftyre.
4.4.1. Turnonthepressuregaugebypressingthe‘U’button(g.5).
4.5. SELECT PRESSURE UNIT
Afterturningonthepressuregauge,pressthe‘U’button(g.5)againtoselecttheairpressureunitsonthedisplay.
NOTE: Conversion relationship of related units is as follow
1PSI=6.89KPA 1BAR=100KPA 1Kg/cm²=98KPA
4.5.1. Tosettheoutputpressurevaluepressthe+or-buttons(g.6).
4.6. INFLATION
Connecttheinatableobjectasshownbelow.
4.6.1. Pressthestart/stopbutton(g.7)tostartinating.Whentheairpressureintheinatedobjectreachesthepresetairpressurevalue,
theairpumpstopsinatingautomatically.
4.6.2. Pressthestart/stopbuttoncanpauseduringtheination,thenpressagaintoresume.
g.4
g.5
g.6
g.7
g.8
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycleunwantedmaterialsinsteadofdisposingofthemaswaste.Alltools,accessoriesandpackagingshouldbesorted,takento
arecyclingcentreanddisposedofinamannerwhichiscompatiblewiththeenvironment.Whentheproductbecomescompletely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
accordingtolocalregulations.
WEEE REGULATIONS
DisposeofthisproductattheendofitsworkinglifeincompliancewiththeEUDirectiveonWasteElectricalandElectronicEquipment
(WEEE).Whentheproductisnolongerrequired,itmustbedisposedofinanenvironmentallyprotectiveway.Contactyourlocalsolid
wasteauthorityforrecyclinginformation.
Note:Itisourpolicytocontinuallyimproveproductsandassuchwereservetherighttoalterdata,specificationsandcomponentpartswithoutprior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.
Original Language Version
© Jack Sealey Limited
CTI120Issue3(2)04/08/20