5. BLOWER REMOVAL (HORIZONTAL DISCHARGE ONLY)
The CC32I Series range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge
configuration, disassemble the blower from the inner top of the hood (see illustrations below). It will be assembled to the inner back of the
hood once the hood is mounted on the wall.
Unplug the blower.
6. INSTALL 3¼” X 10” ADAPTER/DAMPER (HORIZONTAL DISCHARGE ONLY)
Secure the adapter/damper to the back of the hood using 2 no. 8 x 3/8” screws (included). Seal the adapter/damper to the hood using
metal foil duct tape.
NOTE: The wall ducting must be properly prepared to receive the adapter. Before performing the installation, make sure the adapter fits
easily in the duct.
If this hood replaces another one, please note that the location of the air exhaust can vary from one manufacturer to another. In order to
ease a retrofit installation, the horizontal discharge may be positioned on higher OR on lower back of the hood.
According to your needs, the adapter/damper can be installed
to the higher () or lower () back discharge using the
upper screw holes on each side of the adapter/damper. See
illustration beside.
HE0085
Using a 5/16” socket, or a Robertson or a Phillips no. 2
screwdriver, remove all blower mounting screws from the inner
top of the hood. Set aside the blower and its screws.
HD0386
RIGHT SIDE MOUNTING
SCREW LOCATIONS
HD0385
LEFT SIDE MOUNTING
SCREW LOCATIONS
HJ0040
1
2
HIGHER BACK LOWER BACK