14
21. OPERATION
Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to
clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HC0023
B
D
20. CARE (CONT'D)
Hood cleaning
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Do:
Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
You may also use a specialized household stainless steel
cleaner.
Don’t:
Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surface.
C
A
A. DELAY SWITCH:
When a blower speed is selected, press this switch to activate the delay function. The corresponding blower speed switch will flash to
indicate this function is activated. The blower will continue to operate for 5 minutes and will stop automatically.
To cancel the delay function, press the delay switch once again.
B. START/STOP/SPEED SELECTION SWITCH:
Press the switch corresponding to the desired blower speed (from 1 for low speed to 4 for high speed). The chosen switch will light. To
turn off the blower, press once more on the corresponding blower speed switch; the switch light will shut off.
NOTE: When blower is off, pressing on blower speed 1 switch will cause the blower to start on high speed for a very short lapse of
time, and then resume on speed 1.
C. MASTER OFF/FILTER MAINTENANCE/HEAT SENTRY™ (TRIPLE FUNCTION SWITCH):
i. To turn off the blower and the light simultaneously, press this switch once.
ii. After 25 hours of operation, this switch will light to indicate the filters and the blower wheel need to be cleaned in order to maintain
efficient operation of the unit. The switch light will stay on until the function is reset by pressing this switch for 3 seconds.
iii. The light indicator is used for the Heat Sentry function as well.
HEAT SENTRY: When an excessively high temperature is detected, the detector takes control over the blower and set it on speed 3; its
switch light comes on and the Heat Sentry switch flashes.
The blower will remain on until the heat is back to normal, it then returns to the speed previously selected.
WARNING
!
The Heat Sentry can start the blower even if the hood is turned off. When this situation occurs, it is impossible to
turn the blower off using the push buttons. If you must stop the blower, do it from the main electrical panel.
NOTE: In a case of range top grease fire (temperature exceeding 90°C), the Heat Sentry will be deactivated to prevent fire propagation.
D. LIGHT SWITCH:
This switch allows two different lighting levels according to your needs. Press once for full intensity, twice for nightlight.To shut off the
lights without turning the blower off, press once more.
Loading ...