Broan CC32I36SSL Venmar 650 Max Blower CFM, 36" Stainless Steel Chimney Range Hood

INSTALLATION INSTRUCTIONS - Page 5

For CC32I36SSL. Series: CC32I

PDF File Manual, 16 pages, Read Online | Download pdf file

CC32I36SSL photo
Loading ...
Loading ...
Loading ...
5
2. SELECT INSTALLATION TYPE (CONT'D)
Refer to illustrations below to locate duct opening according to discharge type chosen (grey parts to be installed later).
3. REMOVE GREASE FILTERS
Rest the range hood on a table. Remove tape on filters. Remove filters from range
hood by pushing them towards the back and rotate, then set aside the filters.
14
15
16
HK0117A
2
5
16
8
1
16
3
3
16
9¾”
OR
C
L
36” WIDTH HOOD
30” WIDTH HOOD
17
15
16
12¾”
HK0122A
4
3
16
8” DIA.
14
15
16
17
15
16
C
L
36” WIDTH HOOD
30” WIDTH HOOD
VERTICAL DISCHARGE
OR NON-DUCTED
INSTALLATION
HORIZONTAL DISCHARGE
HD0391
1
2
4. CHOOSE THE OPENING
VERTICAL DISCHARGE OR NON-DUCTED INSTALLATION:
Using a Robertson or a Phillips no. 2 screwdriver, remove the 4 top metal plate retaining
screws in order to clear the vertical discharge opening (see illustration beside). Discard
the metal plate and its screws.
HO0142
RETAINING SCREW LOCATIONS
HORIZONTAL DISCHARGE:
In order to ease a retrofit installation, the horizontal discharge may be
positioned on higher OR lower back of the hood.
From outside the unit, remove the knockout for the chosen discharge
opening (see illustrations beside).
HR0038
1
2
OR OR
Loading ...
Loading ...