Zyxel XMG1915-10E-EU0101F XMG1915-10E 8-Port 2.5GbE Smart Managed Switch with 2 SFP+ Uplink

Zyxel XMG1915 Series User Guide - Page 254

For XMG1915-10E-EU0101F.

PDF File Manual, 408 pages, Read Online | Download pdf file

XMG1915-10E-EU0101F photo
Loading ...
Loading ...
Loading ...
Chapter 45 Spanning Tree Protocol
XMG1915 Series User’s Guide
254
45.7 Configure Multiple Spanning Tree Protocol
To configure MSTP, click SWITCHING > Spanning Tree Protocol > MSTP in the navigation panel to display
the screen as shown.
Figure 175 SWITCHING > Spanning Tree Protocol > MSTP > Multiple Spanning Tree Protocol
The following table describes the labels in this screen.
Table 136 SWITCHING > Spanning Tree Protocol > MSTP > Multiple Spanning Tree Protocol
LABEL DESCRIPTION
Bridge
Active Enable the switch button to activate MSTP on the Switch. Disable the switch to disable MSTP
on the Switch.
Note: You must also activate Multiple Spanning Tree (MSTP) in the SWITCHING >
Spanning Tree Protocol > Spanning Tree Setup screen to enable MSTP on the
Switch.
Hello Time This is the time interval in seconds between BPDU (Bridge Protocol Data Units) configuration
message generations by the root switch. The allowed range is 1 to 10 seconds.
Max Age This is the maximum time (in seconds) a switch can wait without receiving a BPDU before
attempting to reconfigure. All switch ports (except for designated ports) should receive BPDUs
at regular intervals. Any port that ages out STP information (provided in the last BPDU)
becomes the designated port for the attached LAN. If it is a root port, a new root port is
selected from among the Switch ports attached to the network. The allowed range is 6 to 40
seconds.
Forwarding Delay This is the maximum time (in seconds) a switch will wait before changing states. This delay is
required because every switch must receive information about topology changes before it
starts to forward frames. In addition, each port needs time to listen for conflicting information
that would make it return to a blocking state; otherwise, temporary data loops might result.
The allowed range is 4 to 30 seconds. As a general rule:
Note: 2 * (Forward Delay 1) >= Max Age >= 2 * (Hello Time + 1)