The isolating switch must be of an approved type and provide a 3 mm air gap contact
separation in all poles (or in all active [phase] conductors if the local wiring rules
allow for this variation of the requirements).
The isolating switch will be easily accessible to the customer with the hob installed.
You consult local building authorities and by-laws if in doubt regarding installation.
You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the
wall surfaces surrounding the hob.
9.3 After installing the hob, make sure that
The power supply cable is not accessible through cupboard doors or drawers.
There is adequate flow of fresh air from outside the cabinetry to the base of the hob.
If the hob is installed above a drawer or cupboard space, a thermal protection
barrier is installed below the base of the hob.
The isolating switch is easily accessible by the customer.
9.4 Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not apply
force onto the controls protruding from the hob
9.5 Adjusting the bracket position
Fix the hob on the work surface by screw 2 brackets on the bottom of hob (see picture).
Adjust the bracket position to suit for different table top thickness.
9.6 Cautions
1.
The hob must be installed by qualified personnel or technicians. We have professionals
at your service. Please never conduct the operation by yourself.
2.
The hob will not be installed directly above a dishwasher, fridge, freezer, washing
machine or clothes dryer, as the humidity may damage the hob electronics