DS-K1A8503 Series Fingerprint Time Attendance Terminal User Manual
5
Chapter 3 Install without Gang Box
Install the device on the wall directly without gang box.
Steps
1. Stick a mounting template on the wall at a required height, and drill 4 holes according to the
mounting template on the wall.
2. Insert 4 supplied expansion sleeves of the setscrews in the drilled holes respectively.
3. Fix and fasten the expansion bolts in the expansion sleeves respectively.
Note
Reserve 5.2 mm to 5.5 mm of expansion bolts outside the wall for hanging the device.
Figure 3-1 Install Expansion Screws
4. Wire the device.
If there is a cable hole on the wall, route the cables from the wall and connect them with the
interfaces on the device rear panel.
If there is no cable hole on the wall, connect the cables with the interfaces on the device rear
panel and make sure the cables will come out from the device bottom.
5. Align 4 holes of the device rear panel with the fixed screws and hang the device on the wall.