49
6. Set the schedule of the face detection. The setup steps of the schedule are the same as
schedule recording setup (See Schedule Recording).
Configuration requirements of camera and surrounding area
1. Cameras must be installed in the area with stable and adequate light sources.
2. The installation height ranges from 2.0m to 3.5m, adjustable according to the focal-length
of different lenses and object distances.
3. The depression angle of the camera shall be less than or equal to 15°.
4. The object distance depends on the focal-length of the lens mounted in the camera.
5. To ensure the accuracy of face detection, the captured faces are only allowed to deviate
less than 30° leftward or rightward or 20° upward or downward.
6. The following scenes are not applicable, like crowded scenes (airport, railway station,
square, etc), backlight scenes, crossroads and so on.
5.5 Network Configuration
5.5.1 TCP/IP
Go to ConfigNetworkTCP/IP interface as shown below. There are two ways for network
connection.
Use IP address (take IPv4 for example): There are two options for IP setup: obtain an IP
address automatically by DHCP and use the following IP address. Please choose one of the
options as needed.
Test: Test the effectiveness of the IP address by clicking this button.