11.
Set linkage method. See Linkage Method Sengs .
8.2.6 Set Unaended Baggage Detecon
Unaended baggage detecon is used to detect the objects le over in the predened area.
Linkage methods are triggered aer the object is le and stays in the area for a set me period.
Before You Start
Go to VCA → Select Applicaon to select Smart Event, and click Next to enable the funcon.
Steps
1.
Go to VCA → Set Applicaon → Smart Event → Unaended Baggage Detecon .
2.
Check Enable.
3.
Oponal: Click to lock PTZ control to prevent the interrupon from other PTZ related acon
during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
4.
Adjust the live image to the desired scene by using PTZ control buons.
5.
Draw detecon area.
1) Click .
2) Click on the live image to draw the boundaries of the detecon area, and right click to
complete drawing.
6.
Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the detecon.
1) Click , and drag the mouse on live image. If you want to change the size, click the buon
and draw again.
2) Click
, and drag the mouse on the live image. If you want to change the size, click the
buon and draw again.
7.
Set detecon parameters.
Sensivity The value of the sensivity denes the size of the object which can trigger the
alarm, when the sensivity is high, a very small object can trigger the alarm.
Threshold It stands for the me of the objects le in the area. Alarm is triggered aer the
object is le and stays in the area for the set me period.