4.
Click OK.
5.
Oponal: Set the switch on the upper right corner to ON to trigger the alarm output.
Congure Parameters for Lane Controller
Aer adding the lane controller to the client, you can congure its parameters for passing through
the lane.
Steps
1.
Click Access Control → Advanced
Funcon → Device Parameter to enter Parameter Sengs
page.
2.
In the device list on the le, select a lane controller and you can edit the lane controller's
parameters on the right.
3.
Edit the parameters.
Passing Mode
Select the controller which will control the barrier status of the device.
●
If you select According to DIP
Sengs, the device will follow the lane controller's DIP
sengs to control the barrier. The sengs on the soware will be invalid.
●
If you select According to Door's Schedule
Sengs, the device will follow the sengs of
the soware to control the barrier. The DIP sengs of the lane controller will be invalid.
Enable Free Passing Authencaon
If you enable this funcon, when both entrance and exit's barrier mode is Remain Open, the
pedestrians should
authencate each me passing through the lane. Or an alarm will be
triggered.
Alarm Voice Prompt Time Duraon
Set how long the audio will last, which is played when an alarm is triggered .
Note
0 refers to the alarm audio will be played unl the alarm is ended.
Temperature Unit
Select the temperature unit that displayed in the device status.
Motor Rotaon Direcon
Set the motor rotaon as Clockwise or Anclockwise. The motor rotaon direcon is the
barrier's open direcon.
Note
●
For single pedestal scenario, the motor rotaon direcon should set as Clockwise.
●
For mulple pedestals scenario, standing at the entrance, the motor rotaon direcon
from right to le should set as: Clockwise, Anclockwise, Clockwise, etc. respecvely.
DS-K3Y220(L)X Series Flap Barrier User Manual