Installing the water heater.
This water heater must be installed in accordance with these instructions, local codes, utility company
requirements, and/or in the absence of local codes, use the latest edition of the American National
Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,
400 N. Capitol Street NW, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54.
Location
The water heater should not be located
in an area where leakage from the tank
or connections will result in damage
to the area adjacent to the heater or to
lower floors of the structure.
When such areas cannot be avoided it is
recommended that a suitable drain pan,
adequately drained, must be installed
under the water heater.
The pan must not restrict air flow to the
combustion air inlet openings (perforation
openings) located around the lower
perimeter of the water heater.
Drain pan kits are available from the store
where the water heater was purchased, or
any water heater distributor.
Make certain the floor underneath the water
heater is strong enough to sufficiently
support the weight of the water heater once
it is filled with water.
A gas-fired water heater or any other
appliance should not be installed
in a space where liquids which give off
flammable vapors are to be used or stored.
Such liquids include gasoline, LP gas
(Butane or Propane), paint or adhesives and
their thinners, solvents or removers.
When installed in a closet, DO NOT
block or obstruct any of the combustion
air inlet openings located around the
perimeter of the water heater. A
minimum of 1” is required between these
combustion air inlet openings and any
obstruction.
Because of natural air movement in a room
or other enclosed space, flammable vapors
can be carried some distance from where
liquids which give off flammable vapors
are to be used or stored. The open flame of
the water heaters pilot or main burner can
ignite these vapors and create a shut down
condition of the water heater which
will not allow the water heater to ignite
until examined by a Qualified Service
Technician.
FVIR certified gas water heaters can be
installed on a residential garage floor
without the use of an 18-inch stand in
accordance with the National Fuel Gas
Code, NFPA 54, ANSI Z223.1, unless
otherwise directed by State and Local
code requirements. The water heater must
be located so it is not subject to physical
damage, for example, by moving vehicles,
area flooding, etc
The water heater should be installed
as close as practical to the gas vent or
chimney.
Long hot water lines should be insulated to
conserve water and energy.
The water heater and water lines should
be protected from exposure to freezing
temperatures.
DO NOT install the water heater in
bathrooms, bedrooms, any occupied
rooms normally kept closed, or in
unprotected outdoor areas.
Minimum clearance from combustible
construction:
* "Front" clearance dimension is measure
from the Combination Gas Control
(Thermostat) to the closet door.
** "Top" clearance dimension is measure
from the jacket top of the water heater to
the ceiling.
If the clearances stated on the Instruction/
Warning Label, located on the front of
the heater differ, install the water heater
according to the clearances stated on the
label.
If the water heater is installed in an
alcove or closet, the entire floor must be
covered by a wood or metal panel.
A minimum of 24” clearance from the
front and top should be available for
adequate inspection and servicing.
The water heater may be installed on
combustible floors, but not directly on
carpeting. If the water heater must be
installed on carpeting, place a metal or
wood panel beneath the water heater,
extending beyond its full width and
depth at least 5” in all directions.
NOTICE: For proper operation and
maintenance, a minimum clearance of
1.5 inches must be provided from the
combination temperature and pressure
relief valve to any wall or object.
WARNING: Combustible
construction refers to
adjacent walls and ceilings
and should not be confused
with combustible or
flammable products and
materials. Combustible
and/or flammable products
and materials should never
be stored in the vicinity of
this or any gas appliance.
!
Combustion Air Inlet
Openings
The auxiliary drain pan
installation MUST conform
to local codes.
Diameter of
water heater
plus 2” min.
Max.
2
Location Front * Sides Rear Top **
Alcove
3”
0” 0” 12”
Closet
3”
0” 0” 12”