Richmond 12GRX40-40F Encore 40 Gallon 40,000 BTU Tank Natural Gas Water Heater

Use & Care Manual - Page 16

For 12GRX40-40F.

PDF File Manual, 28 pages, Read Online | Download pdf file

12GRX40-40F photo
Loading ...
Loading ...
Loading ...
16
Tee fitting for vertical hot
water supply lines.
Hot water
supply to
house
From HOT
outlet on
water heater
Hot water
supply to
heating
unit
Supplemental instructions for gas water heaters installed in
potable/space heating applications.
Local codes or plumbing authority requirements may vary from the instructions or diagrams provided in this
manual and take precedent over these instructions.
Tee fitting for horizontal hot
water supply lines.
From HOT
outlet on
water heater
Hot water
supply to
house
Hot water supply
to heating unit
Combination Potable and Space Heating Application
Tee fitting must be installed as shown. This
ensures that any air in the water lines will be
purged through the domestic water faucets and
showers.
DANGER: When this system requires
water for space heating at elevated
temperatures [above 125°F (52°C)], a mixing
valve complying with the Standard for
Temperature Actuated Mixing Valves for Hot
Water Distribution Systems, ASSE 1017 must
be installed in the hot water supply line to
the house in order to reduce the scald hazard
potential.
DANGER: Any piping or components used
in the installation of this water heater in a
combination potable and space heating
application must be suitable for use with
drinking water.
NOTICE: Suitable for combination water
(potable) heating and space heating and not
suitable for space heating applications only.
DANGER: If this water heater is installed
in an application intended to supply domestic
hot water needs and hot water for space
heating purposes, DO NOT connect the
heater to an existing heating unit or
components of a heating system that have
previously been used with a non drinking
water system. Toxic chemicals such as those
used for boiler treatment may be present and
will contaminate the drinking water supply
causing possible health risks. Never introduce
toxic chemicals, such as those used for boiler
treatment, into this system.
NOTICE: 50' - 0" maximum distance
from water heater to fan coil (developed
length) is required for Massachusetts State.
Typical Piping Diagram for Combination Potable/Space Heating Installation
Spring loaded check valve in
heating unit hot water supply line
and cold water return line (not
supplied with water heater)
NOTICE: This check valve is
incorporated in some heating
units. Refer to the installation
instructions supplied with
specific heating unit to
determine if it is required.
All water piping shall be
insulated in accordance
with Local and State
Energy Code.
Isolation valve in
cold water return line
from heating unit (not
supplied with water
heater)
Nominal 3/4" size mixing or tempering valve
(refer to warning above). Follow mixing or
tempering valve manufacturer’s instructions for
installation of the valve.
Temperature and
pressure relief valve
discharge line
Air Handler
Drain valve
(not supplied with water heater)
Hot water
to space heater
Temperature and
Pressure Relief
Valve, tie to location
approved by local
code
Isolation valve in hot water
supply line to heating unit (not
supplied with water heater)
3/4" cold water supply
3/4" Tempered
domestic hot water
supply to house.
Gas line to water heater
6” Air Gap
Combustion Air Inlet
Openings
2 Gallon Thermal
Expansion Tank (if
required-not supplied
with water heater)
Air vent
Heat Trap
6” Min.
3/4" Shut-Off Valve (Typ.)
3/4" Check Valve with 1/8" Hole
Pressure Gauge
3/4" Shut-Off
Valve (Typ.)
3/4" Shut-
Off Valve
(Typ.)
Piping loop between water
heater and fan coil shall
be flow guard gold CPVC
or equal
Hot water coil
All bronze pump.
Check valve internal
in pump.
Air bleed valve.
Water Sample Tap.
T
FAN
ON
OFF
HEAT
COOL
To HVAC
Unit.
Electronically controlled pump timer.
Activates every 6 hours for 60 seconds.
Wire to bronze pump.
3/4" HWS & HWR
to Heating Coil.
Minimum of 2'-0" developed length of
3/4" type "L" copper from the water heater
connection.
Water Heater drain pan
installed in accordance
with the Local and State
Code
Water Heater to be in
accordance with the
Local and State Energy
Code
Gas Fired
Water Heater
Gas Direct Vent discharge
must comply with Local and
State Code
Vacuum Relief Valve
(Not Supplied)
If required, install per local codes
and valve manufacturer’s
instructions.
120°F to 130°F
140°F
See diagrams above for proper
pipe application for vertical or
horizontal supply lines.