Combination Gas Control, Status Light Troubleshooting
STATUS LIGHT
CODE
CONDITION POTENTIAL SOLUTION(S)
OFF
Combination Gas Control turned
off
Follow the operating instructions in the Use & Care
Manual to turn on the Combination Gas Control
Pilot not lit Follow the lighting instructions as detailed on this water
heater and it's Use & Care manual to light the pilot
Insufcient power supply (mil-
livoltage)
Check thermopile connector to the Combination Gas
Control to ensure it is properly connected
Check thermopile wires for damage and replace if
needed
Inspect pilot assembly
Constantly lit
Pilot recently extinguished and
Thermopile is cooling down
Temperature knob recently turned
to OFF position
Follow the lighting instructions as detailed on the water
heater and it's Use & Care manual to light the pilot
One (1) blink every three
(3) seconds
Normal Operation
Temperature knob in pilot position
and pilot is lit
Set temperature knob on Combination Gas Control to
desire setting
Two (2) blinks every three
(3) seconds
Low thermopile voltage however
pilot is lit
Check thermopile connector to the Combination Gas
Control to enssure it is properly connected
Check thermopile wires for damage and replace it
needed
Inspect pilot assembly
Four (4) blinks every
three (3) seconds
High water temperature limit
tripped
Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Five (5) blinks every three
(3) seconds
Water temperature sensor failure Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Seven (7) blinks every
three (3) seconds
Combination Gas Control failure Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Eight (8) blinks every
three (3) seconds
False pilot ame signal Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
STATUS LIGHT CODE
STATUS
2
4
5
7
8
1
0
RED
RED
RED
RED
RED
BLUE
-
No.
Light Flashes
Color
Thermopile Voltage Low
High Temperature Shutdown
Temperature Sensor Failure
Gas Control or Valve Failure
Flame Sense Error
Normal Operation
Control Off/Pilot Out
If Pilot is lit, Status Light will briefly stay lit and turn from blue to red when knob is turned to OFF.
If the Status Light is not blinking blue,
relight the pilot. To light Pilot, see Lighting
Instructions on water heater. If Status
Light blinks red more than one flash every
three seconds, see Use & Care Manual.