Asko HID956MC

Product/manual/usage connection installation - Page 59

For HID956MC.

PDF File Manual, 62 pages, Read Online | Download pdf file

HID956MC photo
Loading ...
Loading ...
Loading ...
2 phases (220240 V~, 50-60 Hz).
To reach the rated maximum power a fuse of 48A is needed.
Install a jumper between terminals 1 and 2 and between terminals 4
and 5.
3 phases (220240 V~, 50-60 Hz).
To reach the rated maximum power a fuses of 48A is needed.
Install a jumper between terminals 2 and 3 and between terminals 4
and 5.
Current limiter
See chapter Settings, under parameter Con - Current limiter to set the parameter. This parameter
must be set before any pan is placed on the hob or cooking zone activated
WARNING!
Current limiter setting must be set according to your connection and circuit breakers by a
registered and qualified installer. Please read the Safety regulations and the Installation instruction
carefully.
WARNING!
Setting a lower value of the Current limiter parameter may cause a reduced performance of the
induction hob.
59
Electrical installation
Loading ...
Loading ...
Loading ...