motor specifications and
This machin6 is designed to use a 3450 RPM motor only.
Do not use any motor that runs faster than 3450 RPM. It is
wired for operation on 110-120 volts, 60 Hz., atternating
current, IT MUST NOT BE CONVERTED TO OPERATE
ON 230 VOLTS. EVENTHOUGH SOME OFTHE RECOM-
MENDED MOTORS ARE DUAL VOLTAGE.
THESE CRAFTSMAN MOTORS HAVE BEEN
FOUND TO BE ACCEPTABLE FOR USE ON
THIS TOOL.
HP RPM VOLTS CATALOG NO.
1/2 3450 110-120 12!6
1/2 3450 110-220 1218
3/4 3450 110-120 1219
3/4 3450 110-120 1226
CAUTION: Do not use blower or washing machine motors
or any motor with an automatic reset overload protector as
their use may be hazardous.
CONNECTING TO POWER SOURCE OUTLET
This machine must be grounded while in use to protect the
operator from electric shock.
Plug power cord into a110-120V properly grounded type
outlet protected by a !5-amp, dual element time delay or
Circuit-Saver fuse or circuit breaker.
If you are not sure that your outlet is properly grounded,
have it checked by a qualified electrician.
WARNING: DO NOT PERMIT FINGERS TO TOUCH THE
TERMINALS OF PLUGS WHEN INSTALLING OR
REMOVING THE PLUG TO OR FROM THE OUTLET,
WARNING: IF NOT PROPERLY GROUNDED THIS
POWER TOOL CAN INCUR THE POTENTIAL HAZARD
OF ELECTRICAL SHOCK. PARTICULARLY WHEN USED
IN DAMP LOCATIONS IN PROXlMITYTO PLUMBING. IF
AN ELECTRICAL SHOCK OCCURS THERE IS THE
POTENTIAL OF A SECONDARY HAZARD SUCH AS
YOUR HANDS CONTACTING THE CUTTING BLADE.
If power cord is worn or cut, or damaged in any way, have
it replaced immediately.
PROPERLY
GROUNDED
OUTLET\
3--PRONG
GROUNDING
PRONG
This power too! isequipped with a :?,-conductor cord and
grounding type plug which has a grounding prong listed
by Underwriters_ Laboratories Association. The ground
conductor has a green jacket and is attached to the tool
housing at one end and to the ground prong in the
attachment plug at the other end.
This ptug requires a mating 3-conductor grounded type
outlet as shown.
electrical requirements
If the outlet you are planning to use for this power tool is of
the two prong type DO NOT REMOVE OR ALTER THE
GROUNDING PRONG tN ANY MANNER. Use an adapter
as shown and always connect the grounding lug to known
ground.
It is recommended that you have a qualified electrician
replace the TWO prong outlet with a property grounded
THREE prong outlet.
A temporary adapter as shown betow is available for
connecting plugs to 2-prong receptacles. The green
grounding lug extending from the adapter must be con-
nected to a permanent ground such as to a properly
grounded outlet box.
A temporary adapter as illustrated is available for con-
necting plugs to 2-prong receptacles. The temporary
adapter should be used only until a properly grounded
outlet can be installed by a qualified electrician.
GROUNDING LUG
t _1 MAKE SURE THIS IS
3-PRONG _L- _, _._--'*_-'_-_ CONNECTED TO A
PLUG I ll KNOW.GROU.O
/ RECEPTACLE
ADAPTER
WARNING: THE GREEN GROUNDING LUG EXTENDING
FROM THE ADAPTER MUST BE CONNECTED TO A
PERMANENT GROUND SUCH AS TO A PROPERLY
GROUNDED OUTLET BOX, NOT ALL OUTLET BOXES
ARE PROPERLY GROUNDED.
tf you are not sure that your outlet is properly grounded,
have it checked by a qualified electrician.
NOTE: The adapter illustrated isfor use only if you already
have a properly grounded 2-prong receptacle.
The use of any extension cord will cause some toss of
power, To keep this to a minimum and to prevent over-
heating and motor burn-out, L_se the table below to
determine the minimum wire size (A.W.G.) extension
cord. Use oniy 3 wire extension cords which have 3 prong
grounding type plugs and 3-pole receptac}es which wif_
accept the plug on the saw
Extension Cord Length Wire Size A.W.G.
Up to 100 Ft. 14
100 - 200 Ft. 12
2OO- 4OOFt 8
CHECK MOTOR ROTATION
Place the motor on your workbench or on the floor.
Standing clear of the motor shaft, plug the motor cord into
a properly grounded outlet. Notice the rotation of the
shaft. As you look directly at the motor shaft it shoutd be
turning in the counterclockwise direction,_--'_, if the
motor shaft isturning counterclockwise, remove the plug
from the power outlet and continue the assembly pro-
cedures If the motor isturning clockwise, remove the piing
from the power outlet and contact your Sears Store
immediately.