To stop the product
1. Release the power trigger.
2. Push the stop button and then the green LED light
goes off.
3. Remove the battery from the product. Push the 2
release buttons and pull out the battery. (Fig. 51)
Maintenance
Introduction
WARNING: Read and understand the
safety chapter before you do maintenance
work on the product.
WARNING: Remove the battery before
you do maintenance on the product.
Maintenance schedule
WARNING: Remove the battery before
you do maintenance.
The following is a list of the maintenance steps that
you must do on the product. Refer to the tasks in the
maintenance chapter for more information.
Maintenance Daily Weekly Monthly
Clean the external parts of the product with a
dry cloth. Do not use water.
X
Make sure that the start and stop button
works correctly and are not damaged.
X
Make sure that the power trigger and the
power trigger lockout function correctly from
a safety point of view.
X
Make sure that all controls work and are not
damaged.
X
Keep the handles dry and clean. Makes sure
that that there is no oil and grease on the
handles.
X
Make sure that the saw chain cover is not
damaged. Replace the saw chain cover if it is
damaged.
X
Make sure that the screws and nuts are tight. X
Clean the oil tank cap X
Make sure that the battery release buttons
on the battery works and locks the battery in
the product.
X
Examine that the battery charger is not dam-
aged and function correctly.
X
Make sure that the battery is not damaged. X
Make sure that the battery is charged. X
Make sure that the battery charger is not
damaged.
X
Examine all cables, couplings and connec-
tions. Make sure that there is no damage or
dirt.
X