Temperature Limiting (Requiresroom air sensor kit-RAVRMS)
Temperature limiting can reduce energy costs
by limiting the lowesttemperature that can be
set for cooling and the highest temperature that
can be set for heating.Temperature limiting is
controlled by switches 1-6 on the top block
of auxiliary controls. Thefirst three switchesare
usedto select the cooling limits.Thenext three
switches are usedto control the heating limits.
TL3(C)(Temp. Limit S-Cool)
TL2(C)(Temp. Limit 2-Cool)
TL! (C)(Temp. Limit Z-Cool)
I-L! (H)(Temp. Limit !-Heot)
_]-L2 (H)(Temp. Limit 2-Heot)
_TL3 (H)(Temp. Limit 3-Heot)
Temperature limiting during COOL mode
(oil temperatures shown in °F)
Minimum Maximum
60 ° 85 °
64 ° 85 °
66 ° 85 °
68 ° 85 °
70 ° 85 °
72 ° 85 °
74 ° 85 °
76 ° 85 °
UP DOWN
NONE !, 2, 3
1 2,3
1,2 3
2 1,3
2,3 1
!, 2, 3 NONE
1,3 2
3 1,2
* Not opplicoble to Cool-Only models
Temperature limiting during HEAT mode
(oil temperatures shown in °F)*
UP DOWN Minimum Maximum
NONE 4, 5, 6 60° 85 °
4 5, 6 60° 80 °
4, 5 6 60° 78 °
5 4, 6 60° 76 °
5,6 4 60° 74 °
4, 5, 6 NONE 60° 72 °
4, 6 5 60° 70 °
6 4, 5 60 ° 65 °
5