Installation
Instruction
Zoneli
Co iti
e
Air
r$
i Questions? Visit our Website at: GEAppliances.com or call 800.GE.CARES (800.432.2737). i
BEFORE YOU BEGIN
Readthese instructions completely and carefully.
. IMPORTANT - Savetheseinstructions
for local inspector's use.
" IMPORTANT - Observe all governing
codes and ordinances.
. Note to Installer - Be sure to leave these
instructions with the owner,
. Note to Owner - Keepthese instructions
for future reference.
. Proper installation isthe responsibility of the installer.
. Product failure due to improper installation is not
covered under the Warranty.
. You MUSTuse all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
TOOLS YOU WILL NEED
Phillipsscrewdriver
Saw
Tope measure
Adjustablewrench
Hammer
IMPORTANT ELECTRICAL
SAFETY-READCAREFULLY
A WARNING: RISKOFELECTRICSHOCK.
. All electrical connections and wiring MUST
be installed by a qualified electrician.
. Follow the National Electrical Code (NEC)
and/or local codes and ordinances.
o
o
For personal safety, this Zoneline unit and case must
be properly grounded.
Protective devices (fuses or circuit breakers)
acceptable for Zoneline installations are specified on
the nameplate of each unit.
Do not use an extension cord with this unit.
Aluminum building wiring may present special
problems-consult a qualified electrician.
When the unit is not running there isstill voltage to
the electrical controls.
Disconnect the power to the unit before
servicing by:
1. Removing the power cord (if it has one) from
the wall receptacle.
OR
2. Removing the branch circuit fuses or turning
the circuit breakers off at the panel.
,_WARNING: RISKOF ELECTRICSHOCK.
Can cause injury or death. This appliance must be
properly grounded. Where a 2-prong wall outlet is
encountered, it is your responsibility and obligation
to have it replaced with a properly grounded 3-prong
outlet.