Installation Instructions
[_JINSTALL AND CONNECT THE CASE
1.Removethe front case panel and pull
the unit out of the case.Placethe empty case onto
the platform in the closet with the outdoor sidefacing
the wall plenum opening. Align the case with plenum
opening and attach with six field-supplied sheet metal
screws (corrosion-resistant screws recommended).
2. Adjust all four leveling legsuntilthe case is level.
Inside
Air
discharge
outlet
Leveling legs
3. Using field-supplied screws, bolt the case
to the platform.
4. Connect the internal or external drain(s)asnecessary.
iiiiiiii
iiiiiiii
iiiiiiii
iiiiiiii
iiiiiiii
iiii
iiii
iiii
NOTE:Piping is not
supplied with the unit.
Obtain locally.
Secondary _/' drain
option. If not used,
Bolt case
to platform
-%
iiiiiiiiiiiiiiii_i_
External
drain
OR
: "_------------_---- Internal
drainls)
[_]INSTALL AND GROUND
THE UNIT TO THE CASE
UNIT INSTALLED THROUGH FRONT OF CASE
1. Slidethe back of the unit into the case, Pushthe unit
all of the way into the case until it stops,
NOTE:Eitherof the case sides may be removed
to enable the unit to be slid into the case.
2. Ground the unit to the case by installing the front
case-to-unit hex-bolt and discard the two case-to-unit
sidescrew.
Side screw jay
[_]INSTALL AND GROUND
THE UNIT TO THE CASE
UNIT INSTALLED THROUGH SIDE OF CASE
1. Slidethe side ofthe unit intothe case.Pushthe unit
all of the way into the case until it stops.
NOTE:Eitherof the case sides may be removed
to enable the unit to be slid into the case.
2. Attach the case sidepanel to the main case.
3. Ground the unit to the case by installing the front
unit-to-case hex-bolt and discard the two case-to-
unit side screw.