Elica ESC628SS Scanno 28" Stainless Steel Hood Insert

Use, Care, and Installation Guide - Page 4

For ESC628SS. Series: ELICA PRO SERIES
Also, The document are for others Elica models: ETR628SS, ESC134SS

PDF File Manual, 32 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
4
Electrical & installation requirements
IMPORTANT
Observe all governing codes and ordinances.
Itisthecustomer’sresponsibility:
Tocontactaqualiedelectricalinstaller.
To assure that the electrical installation is adequate and in
conformancewithNationalElectricalCode,ANSI/NFPA70—
latestedition*,orCSAStandardsC22.1-94,CanadianElectrical
Code,Part1andC22.2No.0-M91-latestedition**andalllocal
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommendedthataqualiedelectriciandeterminethatthe
ground path is adequate.
Do not ground to a gas pipe.
Checkwithaqualiedelectricianifyouarenotsurerangehood
is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
SaveInstallationInstructionsforelectricalinspector’suse.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect(Orcircuitbreaker)boxthroughmetalelectrical
conduit.
If provided with an electrical plug, connect the hood to a
receptacle that complies with current regulations and placed
in an accessible position. Where an electrical plug is not
provided(directconnectiontoelectricalnetwork)ortheplug
will not be in an accessible position after installation, place an
approved bipolar switch in accessible position that provides full
disconnection under overvolta- ge category III conditions, in
accordance with local wiring rules.
WiresizesmustconformtotherequirementsoftheNational
ElectricalCodeANSI/NFPA70—latestedition*,orCSA
StandardsC22.1-94,CanadianElectricalCodePart1and
C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.
AU.L.-orC.S.A.-listedconduitconnectormustbeprovidedat
eachendofthepowersupplyconduit(attherangehoodandat
thejunctionbox).
Copies of the standards listed may be obtained from:
*NationalFireProtectionAssociationBatterymarchParkQuincy,Massachusetts02269
**CSAInternational8501EastPleasantValleyRoadCleveland,Ohio44131-5575
BEFORE INSTALLING THE HOOD
1 Forthemostefcientairowexhaust,useastraightrunoras
few elbows as possible.
CAUTION:Ventunittooutsideofbuilding,only.
2 Atleasttwopeoplearenecessaryforinstallation.
3 Fittings material is provided to secure the hood to most types
ofwalls/ceilings,consultaQualiedInstaller,checkifthey
perfectlytwithyourcabinet/wall.
4 Donotuseexducting.
5 COLDWEATHERinstallationsshouldhaveanadditional
backdraftdamperinstalledtominimizebackwardcoldairow
andanonmetallicthermalbreaktominimizeconductionof
outside temperatures as part of the ductwork. The damper
should be on the cold air side of the thermal break. The break
should be as close as possible to where the ducting enters the
heated portion of the house.
6 Makeupair:Localbuildingcodesmayrequiretheuseof
Make-UpAirSystemswhenusingDuctedVentilationSystems
greaterthanspeciedCFMofairmovement.Thespecied
CFMvariesfromlocaletolocale.ConsultyourHVAC
professionalforspecicrequirementsinyourarea
Product Dimensions
A
G
E
F
I
D
C
B
H
J
J
Models
ESC628SS ETR628SS ESC134SS
A
28½”(71.9cm) 34½”(87.6cm)
B
15
3
4”(39.8cm) 18”(45.7cm) 15
3
4”(39.8cm)
C
5
7
16”(13.8cm)
D
6
1
2”(16.4cm)
E
22"(56cm) 27
9
16”(70cm)
F
12
3
8”(31.4cm)
G
24"
5
/
16
(61.8cm) 29
13
16”(75.7cm)
H
10
1
16
”(25.6cm)
I
10”(25.4cm)
J
3
4”(1.9cm)
Loading ...
Loading ...
Loading ...