BRGC6001BLK Brohn 60cm 4 Burner Gas Glass Cooktop

User Manual - Page 23

For BRGC6001BLK.

PDF File Manual, 28 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
P a g e |
23
web: brohn.com.au
Gas pressure may be checked on a semi-rapid hob burner. Remove the appropriate
injector and attach a test nipple. Light the other burners and observe that the gas
pressure complies with the gas standards in force.
IMPORTANT: On completion carry out a gas soundness test.
GAS ADJUSTMENT (CONVERSION TO LPG)
All gas adjustment or conversion work must be carried out by a licensed
gas fitter.
IMPORTANT: Always isolate the hob from the electricity and gas supply
before changing the injectors and/or adjusting the minimum flow of the
burners.
Remove the pan-stands, burners and flame spreaders (A).
Unscrew the injector (B) and replace it with the stipulated injector for the new
gas supply (see table on next page).
GENERAL INJECTORS TABLE
Kind of gas
Nozzle
mm
Burners
Power (MJ/h)
Max.
Min.
Natural
1.80
Wok
14.4
6.3
1.49
Rapid
10.8
5.4
1.16
Semi-rapid
6.5
3.24
0.85
Auxiliary
3.6
1.8
Universal LPG
1.07
Wok
14.7
6.3
0.93
Rapid
11.0
5.4