Installation
WARNING
Never test for leaks with a ame!!!
WARNING
This appliance must only be operated with the gas type indicated on the dryers data
plate. If the appliance is converted (gas type changed), a data plate amendment must
be obtained from the manufacturer (dryer’s serial number is required to purchase a
conversion kit).
IMPORTANT
Any burner changes or conversions must be made by qualied personnel.
CONVERSION FROM NATURAL GAS TO PROPANE GAS
WARNING
This procedure must be carried out by a qualied, licensed gas-appliance technician.
Disconnect electrical power to the dryer.
Close all shut-off valves in the dryers gas supply line.
Open the toe panel of the dryer.
Disconnect ignitor wires from harness and
then remove the burner tube.
Remove the burner orice from the valve
and replace it with the proper orice. Use
orice # 44 for NG and orice # 55 for LP.
Orice number is stamped on the edge of
the hex head of the orice. Securely tighten.
Put the burner tube on the burner assembly.
Securely tighten.
Reconnect the ignitor to the harness.
Observe the cover dial settings indicated
as NG and LP along with the gas type
indicator.
Position a pair of needle nose pliers into the
slots of the cover dial.
Rotate the cover dial to line up with LP
marking with the indicator on the gas valve.
WARNING
Improper FUEL Conversions can result in re or explosion!