108
15.4.3 Measurement Grid
The 2 control features - Voltage per division and Time per division – enable
the users to adjust the scope settings to suit the particular test measurement.
Figure 15-7 Sample Measurement Grid
⚫ Voltage per division – shown down the left side of the screen, referred to
as the Y-axis
⚫ Time per division – shown along the bottom of the screen, referred to as
the X-axis
Multiple Scope Channels
The MaxiScope software features multiple channel display which enables
more than one waveform to be displayed at the same time. It is useful for
making comparisons among different signals. The voltage per division for
each channel is adjusted individually while the time base per division is the
same for all channels.
➢ To adjust the voltage scale
1. Tap the specific Y-axis of the corresponding channel to enable
scale adjustment. The selected Y-axis is highlighted with thicker
dividing line.
2. Adjust the voltage scale of the selected channel with the typical
2-finger zoom gestures.