Waldorf BPL8120EE 800 Series 1200mm Electric Tilting Bratt Pan Low Back Version

Installation Operation Manual - Page 5

For BPL8120EE.

PDF File Manual, 24 pages, Read Online | Download pdf file

BPL8120EE photo
Loading ...
Loading ...
Loading ...
3
BP[1]8080E/EE - Electric Bratt Pan Manual/Electric Tilt, 900 mm wide (80 ltr).
BP[1]8120E/EE - Electric Bratt Pan Manual/Electric Tilt,1200 mm wide (120 ltr).
NOTE:
[1]: - Model Options;
- - Standard.
L - Low Back.
B - Bold Front.
LB - Low Back and Bold Front.
BP8080E / EE (80 ltr) Models.
A commercial heavy duty, electric fired Bratt Pan fitted with an 80 ltr capacity pan, of full stainless steel
pan construction, with 3 x 4 kW stainless steel sheathed elements clad to the pan base giving even heat
distribution. This appliance features an electric thermostat burner control and over temperature safety
cut-out.
Created for compact modular kitchens, it is fitted with manual (BP8080E models) or electrical
(BP8080EE) operated tilting mechanism with burner cut-out when the pan is tilted.
BP8120E / EE (120 ltr) Models.
A commercial heavy duty, electric fired Bratt Pan fitted with an 120 ltr capacity pan, of full stainless
steel pan construction, with 3 x 5.66 kW stainless steel sheathed elements clad to the pan base giving
even heat distribution. This appliance features an electric thermostat burner control and over tempera-
ture safety cut-out.
Created for compact modular kitchens, it is fitted with manual (BP8120E models) or electrical
(BP8120EE models) operated tilting mechanism with burner cut-out when the pan is tilted.
BP8080E/EE - 12kW. 400-415V ac, 50/60Hz, 3P+N+E, 12.0 kW @ 415 V.
Phase loading; L1 = 16.4 A.
L2 = 16.4 A.
L3 = 16.4 A.
BP8120-E/EE - 17kW. 400-415V ac, 50/60Hz, 3P+N+E, 17.0 kW @ 415 V.
Phase loading; L1 = 23.2 A.
L2 = 23.2 A.
L3 = 23.2 A.
When connecting a Waldorf electric appliance to the main supply, ensure that the following is carried
out:-
An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary pol-
ychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191
part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
Electrical supply connection point is located at the rear of the appliance, approximately 87 mm from
the left hand side, 557 mm from the rear and 335 mm (290 mm for BP8120E/EE) from the floor.
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.