Stage and Local I/O Rack Overview 50
Stage and Local I/O Rack Overview
Stage I/O units for S6L systems include Stage 64, Stage 32, and Stage 16.
Stage 64
Stage 64 is modular, and can be configured with a variety of I/O cards. Stage 64
supports up to eight input cards and four output cards, for a total of up to 64 in-
puts and up to 32 outputs (analog or digital).
Stage 64 also provides features such as the Stage 64 Menu with programmable
options and a corresponding display, MADI outputs, word clock output, as well
as a built-in confidence monitor with level control.
Stage 32
Stage 32 is also modular, and lets you connect up to 32 analog, digital, and/or
Dante inputs or outputs in a 5U rack. Integrating Stage 32 into S6L systems re-
quires dual AVB-192 Network Cards in the E6L Engine. Each Stage 32 sup-
ports up to a maximum 32 channels of inputs or outputs or a combination of
both. You can customize Stage 32 with any of the same analog I/O, digital I/O,
and Dante card options available for Stage 64, including SRI-192 Analog Input
cards, SRO-192 Analog Output cards, DSI-192 Digital Input cards, DSO-192
Digital Output cards, and DNT-192 Dante Option cards. Stage 32 also provides
MADI outputs.
Stage 16
Each Stage 16 provides 16 analog inputs, 8 analog outputs, and 4 digital out-
puts. Integrating Stage 16s into S6L systems requires dual AVB-192 Network
Cards in the E6L Engine.
Local 16
Local 16 lets you expand your local I/O capabilities, or add primary local I/O if
mixing on the S6L-16C control surface, by providing 8 XLR mic/line inputs, 8
XLR outputs, 4 pairs of XLR stereo AES/EBU inputs (8 channels total), and 4
pairs of XLR stereo AES/EBU outputs (8 channels total), similar to that on
S6L-32D/24D/24C control surfaces. Up to two Local 16 units can be connected
on the local (console) S6L AVB Network ring when using S6L-16C. A single
Local 16 can be used with other S6L systems. Integrating Local 16s into S6L
systems requires dual AVB-192 Network Cards in the E6L Engine.