16 English
Note
The granulate in the cartridge can discolour on contact
with water due to the mineral content in the water, which
is no cause for concern and has no negative effects on
the device, cleaning work or the functionality of the car-
tridge.
Note
Do not pause for longer than 15 seconds when setting
as the device will otherwise be set automatically to the
last selected water hardness or the highest water hard-
ness set during initial start-up.
1. Connect the mains plug.
2. Make sure that the device is switched off.
3. Press the RESET button and hold it while the device
is switched on.
Illustration G
After approximately 2 seconds, the indicator light
flashes and signals the current water hardness set-
ting with the number of pulses.
4. Press the RESET key repeatedly to change the wa-
ter hardness level.
Note
When the RESET key is pressed, the flash pulse for the
water hardness level is not indicated.
5. Release the RESET key.
The flash pulse for the set water hardness is indicated.
6. Repeat the process as necessary until the desired
water hardness level has been achieved.
7. Press and hold the RESET key for 3 seconds to
save the setting for the water hardness level.
The indicator light for the water hardness lights up.
Care of accessories
(Accessories - depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer.
Note
When washing the cloths, observe the instructions on
the washing tag. Do not use any liquid softeners as this
will affect the ability of the cloths to pick up dirt.
1. Wash the floor cleaning cloths and covers at a max.
temperature of 60 °C in the washing machine.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always
dangerous.
Remove the mains plug.
Allow the appliance to cool down.
The water shortage indicator light flashes red
The dry-run protection for the pump is deactivated.
1. Switch the device off and back on again.
2. Make sure that the decalcification cartridge ha
s
been inserted correctly and there is sufficient water
in the reservoir.
The water shortage indicator light lights up con-
stantly in red
No water in the water reservoir.
1. Top up the water reservoir, see chapter Topping up
the water.
The steam lever cannot be pressed
The steam lever is locked with the child lock.
Set the child lock (selector switch for steam volume)
to the front.
The steam lever is released.
No / little steam although there is water in the reservoir
The decalcification cartridge has not been inserted or
has been inserted incorrectly.
Insert the decalcification cartridge or insert it correctly.
The decalcification cartridge has been removed while
topping up the water.
Leave the decalcification cartridge in the device
when topping up.
New decalcification cartridge has been inserted.
Press and hold the steam lever constantly.
The full steam output is reached after approximately
30 seconds.
Red indicator light "replace descaling cartridge"
lights up / flashes
Run time of the decalcification cartridge ends soon.
Insert the new decalcification cartridge and reset the
maintenance indicator, see chapter Replacing t
he
d
ecalcification cartridge.
The RESET key was not pressed after replacement of
the decalcification cartridge.
Press and hold the RESET key for 4 seconds after
inserting the decalcification cartridge, see chapter
Replacing the decalcification cartridge.
Device switches off automatically
Run time for the decalcification cartridge has expired
Insert the new decalcification cartridge and reset the
maintenance indicator, see chapter Replacing t
he
decalcification cartridge.
The RESET key was not pressed after replacement of
the decalcification cartridge.
Press and hold the RESET key for 4 seconds after
inserting the decalcification cartridge, see chapter
Replacing the decalcification cartridge.
Technical data
Subject to technical modifications.
Electrical connection
Voltage V 220-240
Phase ~ 1
Frequency Hz 50-60
Protection class IPX4
Protection category I
Performance data
Heating capacity W 1900
Maximum operating pressure MPa 0.35
Heating-up time Seconds 30
Continuous steaming g/min 40
Maximum steam blast g/min 100
Filling quantity
Water reservoir l 1.0
Dimensions and weights
Weight (without accessories) kg 3.2
Length mm 360
Width mm 236
Height mm 252