ATTACHING DOUBLE DEPTH UNITS TOGETHER (cont)
Next, using two pipe clamps, pull the units together (see
figure 5). Install the covers over the gap formed between
the units From inside the cabinets, using the screws
provided, install the breaker strips using the strip as a
template.
III. g -
INSTALLING THE CONDENSATE EVAPORATOR
A condensate evaporator is normally supplied on all self-
contained models (remote models require provision of either
a floor drain or an optional condensate evaporator). On
those models supplied with a top-mounted evaporator coil
compartment, the condensate evaporator is also secured
to the top of the cabinet. Check that the condensate pan is
properly located underneath the drain tube.
NOTE: Some models, such as single section dual-
temperature refrigerator/freezers, are supplied with a
bottom-mounted condensate evaporator. This is shipped
in a cardboard carton secured to the cabinet interior, and
must be PROPERLY installed prior to use (see instructions
supplied with the condensate evaporator).
1. After the cabinet has been uncrated and the legs/
casters attached, you must install the bottom-mounted
condensate evaporator.
2. Locate the four (4) holes on the exterior bottom towards
the rear of the cabinet.
3. Using the provided 10-32 screws, attach the mounting
rails to the bottom, (the folded ange is to be turned up
and be towards the drain line).
4. Slide condensate pan into the mounting rails.
5. Screw the “U-Trap” on to the drain line located on the
rear of the cabinet.
III. g -
INSTALLING THE CONDENSATE EVAPORATOR (cont’d)
6. Screw the drain extension into the “U-Trap”.
NOTE: The use of the “U-TRAP” supplied is required. Failure
to use this component may allow cold air to migrate down
the drain line, resulting in condensation on the rear of the
cabinet.
A remote model is normally supplied configured for
condensate to be run to a floor drain unless purchased
with a condensate evaporator. The installer is responsible
for making the required extension to the floor drain in
accordance with good practice and local regulations.
III. h - REMOTE INSTALLATION
Remote models are supplied without compressors, solenoid
valves, etc. The correct voltage, amp listing and refrigerant
are listed on the units serial tag. It is the responsibility of the
installer to specify and supply the correct size compressor(s)
based upon this information and on-site requirements.
Refrigerant line installation must be done in accordance
with good practice and local regulations. See section “III. g”
for information concerning condensate removal for remote
models.
III. i - CORD & PLUG
Most self-contained models are supplied with a cord &
plug attached. It is shipped coiled at the top of the cabinet,
secured by a nylon strip. For your safety and protection,
all units supplied with a cord and plug include a special
three-prong grounding plug on the service cord. Select only
a dedicated electrical outlet with grounding plug for power
source.
NOTE: Do not under any circumstances, cut or remove the
round grounding prong from the plug, or use an extension
cord.
Using two pipe clamps,
pull the two units together
and using the screws
provided. Align the breaker
strips as a template for the
screw pattern inside and
outside the cabinet.
Fig. 5
Fig. 6