94 - CLEANING AND MAINTENANCE 91477A627/B
kitchen roll or a microfibre cloth.
If present, remove the temperature probe.
Remove the rack/tray support frames.
Close the door.
Pyrolytic function setting
1. After entering the special functions menu,
press the and touch buttons on
the control panel until the function is
selected.
1. Press the button to confirm.
The display shows the Pyrolytic function duration
(factory set to 2:30 hours).
2. Press the and touch buttons on
the control panel to set the duration of the
Pyrolytic function from a minimum of 2:30
hours to maximum of 3:30 hours.
3. Press the button to confirm.
4. Two minutes after the Pyrolytic cycle starts,
the indicator light comes on to indicate
that the door is locked by a device that
prevents the door from being opened.
End of Pyrolytic function
At the end, is displayed and flashes
and a beep is activated.
1. Press the touch button on the control
panel to exit the function.
2. Open the door and collect the residue
deposited inside the oven cavity with a
damp microfibre cloth.
Recommended pyrolytic cycle duration:
Light dirt: 2:30
Medium dirt: 3:00
Heavy dirt: 3:30
It is not possible to start the pyrolytic
cycle if the temperature probe (if
available) is plugged in.
It is not possible to select any function
once the door lock device has been
activated. The touch buttons remain
deactivated until the function is
completed.
The door is locked until the temperature
inside the oven cavity returns to a safe
level.
During the Pyrolytic cycle the fans
produce a more intense level of noise
due to a greater rotation speed. This is
an absolutely normal operation,
intended to provide more effective heat
dispersal. At the end of the pyrolytic
cycle, the fans will continue to operate
for long enough to avoid overheating
the walls of adjacent units and the front
of the oven.
During the first Pyrolytic cycle,
unpleasant odours may occur due to
the normal evaporation of oily
manufacturing substances. This is an
absolutely normal phenomenon which
disappears after the first pyrolytic cycle.
If the pyrolytic cycle gives unsatisfactory
results at minimum duration, it is
recommended to set a longer time for
subsequent cleaning cycles.
We recommend wearing rubber gloves
for these operations.