Product Data Sheet
Water Filtration System Model WF-L500
(_This product has been tested and certified by NSF International under ANSI/NSF Standard 42 for
Chlorine reduction (Class I), Taste and Odor reduction and to Standard 53 for Lead reduction.
Specifications: Lead and Taste/Odor/Chlorine reduction (Class 1) capacity
500 Gallons (1893 Liters)
Service Flow Rate 0.5 GPM (1.89 L/min) @ 60 psi
General Average Maximum Average Minimum % Average % NSF Test
Performance Influent Effluent Effluent Reduction Reduction Requirement
Chlorine 2.0 mg/L N/A 0.1 mg/L N/A 95% minimum 75% reduction
(Class [)
Contaminant
Reduction U,S. EPA Average Maximum Average Minimum % Average %
Performancett MCL Influent Effluent Effluent Reduction Reduction NSF Test Requirement
Lead @ pH 6.5 0.015 mg/Lt 0.16 mg/Lt 0.007 mg/L 0.005 mg/L 95.6% 96.8% maximum effluent 0.015 mg/L
Lead @ pH 8.5 0.015 mg/Lt 0.14 mg/Lt 0.012 mg/L 0.008 mg/L 91.4% 94.3% maximum effluent 0.015 mg/L
t Test requirement is 0.15 mg/L _+10% tt These contaminants are not necessarily in your water supply.
Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International
Application Guidelines/
Water Supply Parameters
Water Supply City or Well
Water Pressure 30-120 psi (207-827 kPa)
Water Temperature 33°-100°F (0.6°-37.8°C)
It is essential that operational, maintenance, and filter
replacement requirements be carried out for this
product to perform as advertised.
The filter monitor system measures the amount of
water that passes through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is
used, the filter indicator light changes from green to
yellow. When 190% of the filter's rated life is used,
the filter indicator light changes from yellow to red,
and it is recommended that you replace the filter. Use
replacement cartridge part WF-L500 or #4392857.
Suggested retail price of $29.95 U.S.A/$39.95 Canada.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system.