4. The Math Channel displays on the MaxiScope screen
Probe
A probe is any transducer, measuring device or other accessory that you
connect to an input channel of your MaxiScope module.
Reference Waveform
A Reference Waveform is a copy of an existing signal waveform saved as a
reference. It can be retrieved to display as a comparative reference to examine
a live signal. Up to 4 reference waveforms can be saved.
Figure 16-5 Ref. Waveform Save Window
To create a Reference Waveform:
1. Tap the Save button in the Top Menu.
2. Select Save Ref. in the dropdown menu.
3. Select the channel to which the desired waveform belongs.
4. Name the reference waveform by selecting R1, R2, R3 or R4 in the
popup window.
5. Tap on the Yes to save, or No icon to cancel.
Recall Reference
The saved reference waveforms can be retrieved by clicking Recall Ref in the
dropdown menu of the Tool button.
To recall reference waveforms:
1. Tap Tool button on the Top Menu.
2. Select Recall Ref in the dropdown menu and a popup window will
display. Available reference waveform items are highlighted in blue.
3. Select the desired reference waveform by ticking the check box
alongside.
Loading ...