SDG800 User Manual 86
3.2. Example 2:Generate a Square Wave
Generate a square wave with 5kHz frequency, 2Vpp amplitude, 0Vdc offset
and 30% duty cycle.
Steps:
Set the frequency.
1. Press Square →Freq and choose Frequency which will display in white
color.
2. Input ‘5’ from the keyboard and choose the unit ‘kHz’. The frequency is
set to be 5kHz.
Set the amplitude.
1. Press Ampl to choose Ampl which will display in white color.
2. Input ‘2’ from the keyboard and choose the unit ‘Vpp’. The amplitude is
set to be 2Vpp.
Set the offset.
1. Press Offset to choose Offset which will display in white color
2. Input ‘0’ from the keyboard and choose the unit ‘Vdc’. The Offset is set to
be 0Vdc.
Set the duty
1. Press Duty to choose Duty which will display in white color
2. Input ‘30’ from the keyboard and choose the unit ‘%’. The duty is set to be
30%.
When the frequency, amplitude, offset and duty cycle are set, the wave
generated is shown in Figure 3- 2.