Electrical Connections
Unless otherwise shown, the door section is furnished with a factory installed vapor
proof light fixture on the interior of the section, and a light switch with pilot light indicator
flush mounted on the exterior. Freezer door sections are equipped with anti-
condensate heaters around the entire perimeter. Cooler door sections with stainless
steel thresholds are equipped with low-power anti-condensate heaters around the entire
perimeter. Heaters run underneath the thresholds, so care must be used if drilling
through so that the wire does not get damaged.
All wiring in the door and door section for heaters, switch, and light fixtures is factory
installed and requires only simple field connection for complete operation; service
required is 120 volt, 60 cycle, single phase, unless otherwise shown.
Electrical connections for are made on the interior of the door section inside the fixture
base of the vapor proof light. Consult the assembly drawing for the specific electrical
connection point for your unit.