Blue Seal Evolution G570 Series 900mm Gas Target Top Static Oven Range

Installation Operation Manual - Page 7

For G570.

PDF File Manual, 28 pages, Read Online | Download pdf file

G570 photo
Loading ...
Loading ...
Loading ...
5
Specifications
- All Other Markets:
NOTE:
 (**) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
 TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
 Refer to ‘Gas Conversion and Specifications' section of this manual for further
details.
Gas Connection
Gas supply connection point is located at rear of the appliance, 130mm from right hand side, 32mm
from rear and 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’
section).
Connection is ¾" BSP male thread.
Natural Gas Town Gas (**)
Target Top Oven Target Top Oven
Input Rate (N.H.G.C.)
45 MJ/hr 30 MJ/hr 45 MJ/hr 30 MJ/hr
Gas Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 0.95 kPa 0.63 kPa
Gas Connection
3
/
4
” B.S.P. Male
LP Gas (Propane) Butane
Target Top Oven Target Top Oven
Input Rate (N.H.G.C.)
45 MJ/hr 30 MJ/hr 45 MJ/hr 30 MJ/hr
Gas Supply Pressure 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.60 kPa 2.60 kPa
Gas Connection
3
/
4
” B.S.P. Male
Loading ...
Loading ...
Loading ...