Operation
Lighting Pilot Burner - (Target Top)
1. Remove centre casting with casting removal tool.
2. Depress control knob and rotate anti-clockwise to ‘PILOT’ position.
3. With control knob depressed, manually light pilot burner located in front of main burner.
4. Hold in control knob for approximately 10 to 15 seconds, then release.
5. Pilot burner should remain alight. If not repeat Items 2 to 4 above until pilot burner lights.
Lighting Main Burner - (Target Top)
1. Ensure pilot burner is alight by checking through hole in centre of front control panel or by removing
centre casting, with casting removal tool.
2. Rotate gas control knob anti-clockwise to position marked ‘HIGH’.
3. Main burner will now ignite automatically off pilot burner.
4. Once lit main burner will be burning at full rate. For a lower heat turn gas control knob fully anti-
clockwise to ‘LOW’ position.
5. Also for intermediate heat, position gas control knob between ‘HIGH’ and ‘LOW’ positions.
NOTE: Always set gas control knob to ‘HIGH’ position when lighting main burner. If pilot burner
goes out during normal operation wait 5 minutes before re-lighting.
6. Cast iron work surface has a heat pattern that can be used effectively by positioning cooking pans
etc. appropriately according to heat requirement.
350 / 400
300 / 350
250 / 300
200 / 250
Heat Pattern for Target Top on full heat (°C)
Heat Pattern for Target Top on Low Heat (°C)
200 / 250
150 / 200
250 / 300
Fig 4