23
Gas Conversion and Specifications
- All Other Markets:
NOTE:

(*) Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gasses, if required.
 (**) TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas regulator
supplied. Town Gas Option is only available with specific ex-factory built Town Gas models, which
can also be converted to any other gas. Standard models can only be converted between Nat. Gas,
LP Gas and Butane, but not Town Gas.
 Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Natural Gas Town Gas (**)
Target Top
Main Burner Injector (Inner Ring) Ø 1.70mm Ø 4.20mm
Main Burner Injector (Outer Ring) Ø 2.60mm Ø 6.30mm
Pilot Injector 0.35 0.70
Burner Aeration Screw X (Inner) 25mm 20mm
Burner Aeration Screw Y (Outer) 28mm 22mm
Low Fire Adjustment 2
1
/
2
turns out (ccw)
Blank
1
1
/
2
turns out (ccw)
Oven
Main Burner Ø 2.60mm Ø 5.00mm
Pilot Injector 0.35 0.60
Burner Aeration Setting Fully open Fully open
Low Fire Ø 1.5mm Ø 2.50mm
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 1.0 kPa 0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure Specified)
LP Gas (Propane) Butane
Target Top
Main Burner Injector (Inner Ring) Ø 1.10mm Ø 1.00mm
Main Burner Injector (Outer Ring) Ø 1.55mm Ø 1.45mm
Pilot Injector 0.25
Burner Aeration Screw X (Inner) 25mm
Burner Aeration Screw Y (Outer) 28mm
Low Fire 1 turn out (ccw)
Oven
Main Burner Ø 1.60mm Ø 1.45mm
Pilot Injector 0.23
Burner Aeration Setting Fully open
Low Fire Ø 0.95mm
Supply Pressure 2.75 - 4.50 kPa
Burner Operating Pressure (*) 2.6 kPa (*)
Gas Regulator Cap Screw