21
Gas Conversion and Specifications
Gas Specifications
- Australia
- New Zealand:
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Nat. Gas LP Gas (Propane)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70mm Ø 1.10mm
Main Burner Injector (Outer Ring)
Ø 2.60mm Ø 1.55mm
Pilot Burner Injector
0.35 0.25
Burner Aeration Screw X (Inner)
25mm 25mm
Burner Aeration Screw Y (Outer)
28mm 28mm
Low Fire Adjustment
2½ turns out (ccw) 1 turn out (ccw)
Oven
Main Burner
Ø 2.60mm Ø 1.60mm
Pilot Burner
0.35 0.23
Low Fire Screw
Ø 1.5mm Ø 0.95mm
Burner Operating Pressure (*) 1.00 kPa 2.60 kPa
Gas Regulator Cap Screw
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Nat. Gas LP Gas (Propane)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70mm Ø 1.10mm
Main Burner Injector (Outer Ring)
Ø 2.60mm Ø 1.55mm
Pilot Burner Injector
0.35 0.25
Burner Aeration Screw X (Inner)
25mm 25mm
Burner Aeration Screw Y (Outer)
28mm 28mm
Low Fire Adjustment
2½ turns out (ccw) 1 turn out (ccw)
Oven
Main Burner
Ø 2.60mm Ø 1.60mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Low Fire Screw
Ø 1.5mm Ø 0.95mm
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 1.00 kPa 2.60 kPa
Gas Regulator Cap Screw